FORMULA 8200 Fiber Switch Installation Guide
15
IP Addresses
The FORMULA 8200 has a factory-assigned unique MAC address but does not
have a default IP address. If you are managing the switch from a console, an IP
address is not required. However, if you are managing the switch over the
network (via SNMP or Telnet), the switch must have a valid IP address.
Assign a unique IP address to the switch by using the BOOT/IP/CONFIG
command. See the FORMULA 8200 User’s Guide, available from
www.alliedtelesyn.com/manuals.htm, for more details.
Power
Solid green
means power is applied and the switch is
functioning normally. No action is required.
Off
means there is no power to the switch.
Check the power plug and the state of the on/off switch in the back
of the unit. If On, turn it off, wait a few seconds, and turn it on. If
LED remains unlit, replace the switch.
Port LED:
Activity
Flashing or solid green
means the port is receiving or
transmitting traffic. No action is required.
Off
means there is no traffic. This state does not indicate any
problem on that port. No action is required.
Port LED:
Collision
This LED is always
Off
. It is not supported on the FORMULA 8200
fiber switch because collisions do not occur on full duplex FX ports.
No action is required.
Port LED:
Link
Solid green
means the cable’s link status is good.
Off
means there is no link;
flashing
means there is a link
problem. Verify cable and port speed supported on end device (FX
ports are 100Mbps full duplex only).
Port LED:
Diag
This LED is normally
off
. This LED is reserved for factory use.
Table 3: LED States and Recommended Action (Continued)
LED
Description and Action Required
Fiber_Book Page 15 Tuesday, February 17, 1998 1:43 PM
Содержание Formula 8200
Страница 1: ...FORMULA 8200 Fast Ethernet Fiber Workgroup Switch Installation Guide PN 613 10688 00 Rev A...
Страница 4: ......
Страница 24: ......
Страница 26: ......