613-000810 Rev. A

CONVERTEON™ Family

One-Slot Chassis

AT-CV1000

Installation Guide

Содержание Converteon AT-CV1000

Страница 1: ...613 000810 Rev A CONVERTEON Family One Slot Chassis AT CV1000 Installation Guide...

Страница 2: ...ntioned herein are trademarks or registered trademarks of their respective owners Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this docume...

Страница 3: ...ely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note Modifications or changes not expressly approved of by the manufacturer or...

Страница 4: ...The indicates that a translation of the safety statement is available in a PDF document titled Translated Safety Statements posted on the Allied Telesis website at www alliedtelesis com and on the do...

Страница 5: ...ewing Safety Precautions 22 Selecting a Site for the Chassis 23 Unpacking the Chassis 24 Using the AT CV1000 Chassis on a Desktop 25 Mounting the AT CV1000 Chassis on a Wall 26 Installing an AT CV1000...

Страница 6: ...Contents 6...

Страница 7: ...11 AT CVMCR Installation Adapter 28 Figure 12 Removing the Mounting Rail from a Slot in the AT MCR12 Chassis 29 Figure 13 Installing the AT CVMCR Adapter on the AT CV1000 Chassis 29 Figure 14 AT CV100...

Страница 8: ...Figures 8...

Страница 9: ...tions on how to install an AT CV1000 One Slot Converteon chassis This preface contains the following sections Safety Symbols Used in this Document on page 10 Where to Find Web based Guides on page 11...

Страница 10: ...s the safety symbols defined in Table 1 Table 1 Safety Symbols Symbol Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data Warning Perfor...

Страница 11: ...ind Web based Guides The installation and user guides for all Allied Telesis products are available in portable document format PDF on our web site at www alliedtelesis com You can view the documents...

Страница 12: ...materials authorization RMA number A product sent to Allied Telesis without an RMA number will be returned to the sender at the sender s expense To obtain an RMA number contact the Allied Telesis Tech...

Страница 13: ...3 Chapter 2 Overview This chapter contains the following sections Features on page 14 Converteon Line Cards on page 16 Blank Slot Cover on page 17 Power Adapter on page 18 Network Topologies on page 1...

Страница 14: ...s on a desktop as a standalone media converter mount it on a wall or install it in an AT MCR12 chassis In addition you can install the AT CV1000 chassis in an AT MCR12 media converstion rack mount cha...

Страница 15: ...lot Chassis Installation Guide 15 Figure 2 shows the front and back panels of the AT CV1000 chassis Figure 2 AT CV1000 Chassis Front and Back Panels AT CV1000 266 12VDC AT CVPNLx Blank Slot Cover AC P...

Страница 16: ...For a current list of Converteon line cards refer to the Allied Telesis web site or consult your authorized sales representative For detailed descriptions of these line cards refer to the documentati...

Страница 17: ...airflow cooling and ventilation throughout the chassis Figure 1 illustrates the AT CV5PNL1 blank slot cover Figure 3 AT CV5PNL1 Blank Slot Cover Note Allied Telesis strongly recommends that a blank sl...

Страница 18: ...Chapter 2 Overview 18 Power Adapter The AT CV1000 chassis uses a two part AC power adapter supplied as shown in Figure 4 Figure 4 AC Power Adapter 517...

Страница 19: ...09FC switch connected to the 100Base FX port on the AT CM202 line card in the AT CV1000 media converter Network 2 has an AT 8524M switch connected to the 10 100Base TX port on the AT CM202 line card i...

Страница 20: ...nverter Network 2 has an AT 8524M switch connected to the 10 100Base TX port on the AT CM202 line card in the second AT CV1000 media converter Figure 6 Back to Back Network Topology AT CM202 RDY T X F...

Страница 21: ...n page 23 Unpacking the Chassis on page 24 Using the AT CV1000 Chassis on a Desktop on page 25 Mounting the AT CV1000 Chassis on a Wall on page 26 Installing an AT CV1000 Chassis in an AT MCR12 Rack M...

Страница 22: ...ment must be earthed The power plug must be connected to a properly wired earth ground socket outlet An improperly wired socket outlet could place hazardous voltages on accessible metal parts E4 Plugg...

Страница 23: ...te should provide easy access to the ports on the front and the power supply on the back of the chassis This arrangement will make it easy for you to connect and disconnect cables as well as to view t...

Страница 24: ...e unit to Allied Telesis 2 Make sure that the following components are included in the package If any item is missing or damaged contact your Allied Telesis sales representative for assistance One AT...

Страница 25: ...adhesive rubber feet included to the bottom of the chassis as shown in Figure 7 Figure 7 Attaching Rubber Feet 4 Turn the chassis over again 5 Install the line card according to the instructions in I...

Страница 26: ...from the chassis 2 Install the line card according to the instructions in Installing a Converteon Line Card on page 32 3 Install the provided wall mount brackets onto the chassis as illustrated in Fi...

Страница 27: ...o secure the brackets against the wall Figure 10 Positioning The AT CV1000 Chassis Onto the Wall Screws 8 Cable the line card according to the instructions that were shipped with the line card 9 Power...

Страница 28: ...n determines how many media converters the AT MCR12 chassis can support before the primary power supply shuts down To avoid power problems Allied Telesis strongly recommends that you calculate the tot...

Страница 29: ...m a Slot in the AT MCR12 Chassis 2 Turn the AT CV1000 chassis upside down 3 Turn the AT CVMCR adapter over align it with the base of the chassis and attach it to the chassis with two screws provided a...

Страница 30: ...0 chassis into the AT MCR12 chassis as shown in Figure 15 Figure 15 Sliding the AT CV1000 into the AT MCR12 Chassis Slot 6 Press gently on the AT CV1000 chassis to seat the chassis into the backplane...

Страница 31: ...s as shown in Figure 16 Figure 16 Tightening the Captive Screw on the AT CVMCR Adapter 8 Install the line card according to the instructions in Installing a Converteon Line Card on page 32 1253 MEDIA...

Страница 32: ...the AT CV1000 Keep the blank slot cover in a safe area in case you remove the line card The blank slot cover is used to keep dust from getting into the chassis and maintains proper airflow cooling and...

Страница 33: ...ides 5 Align the back edge of the line card with the left and right alignment guides located inside the slot 6 Slide the line card into the slot as shown in Figure 18 until the slot cover is flush wit...

Страница 34: ...e 19 Tightening the Captive Screw Note Always tighten the captive screw to secure the line card to the chassis Refer to the documentation shipped with your line card or to the Converteon Media Convert...

Страница 35: ...QQGQ or EPBU TUV Licensed or other Safety Agencies approved and that are suitable for country of use To power on an AT CV1000 chassis perform the following procedure 1 Plug one end of the power cord...

Страница 36: ...ready for network operations Warning Power cord is used as a disconnection device To de energize equipment disconnect the power cord E3 Pluggable Equipment The socket outlet shall be installed near th...

Страница 37: ...be inserted in the AT CV1000 chassis when it does not contain a functioning line card To install an AT CV5PNL1 blank slot cover perform the following procedure 1 Disconnect the cables from all the por...

Страница 38: ...river to tighten the captive screw as shown in Figure 22 Figure 22 Tightening the Captive Screw on an AT CV5PNL1 Blank Slot Cover Note Always tighten the captive screw to secure the blank slot cover t...

Страница 39: ...AT CV1000 One Slot Chassis Installation Guide 39 Warranty Registration...

Страница 40: ...er limited warranties Some products have a longer warranty coverage than others The AT CV1000 chassis has a limited warranty of Lifetime 24 months Fan PSU All Allied Telesis warranties are subject to...

Страница 41: ...tal Specifications Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 25 C to 70 C 13 F to 158 F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing Maxi...

Страница 42: ...afety and Electromagnetic Emissions Certifications EMI FCC Class A EN55022 Class A VCCI Class A C TICK CE Immunity EN55024 Safety UL60950 1 CULUS EN60950 1 TUV CAN CSA C22 2 No 60950 1 Laser EN60825 Q...