Страница 1: ...CentreCOM AT 810SL Multiport Transceiver Fanout Version 2 User Manual...
Страница 2: ...lated to this manual or the information contained herein even if Allied Telesyn International Corp has been advised of known or should have known the possibility of such damages Trademarks Ethernet is...
Страница 3: ...TO VOLTAGE ADJUSTMENT This product will automatically adjust to any voltage between the ranges shown on the label U S Federal Communications Commission RADIATED ENERGY Note This equipment has been tes...
Страница 4: ...Klasse B entspricht Wenn dieses Produkt nicht mit entst rten Kabeln verwendet wird k nnte es Funkst rungen hervorrufen der Anwender m te in diesem Fall angemessene Gegenma nahmen ergreifen St rsicher...
Страница 5: ...ves brugeren muligvis at tage tilstr kkelige foranstaltninger Immunitet EN50082 1 SIKKERHED Elektrisk sikkerhed EN60950 UL1950 CSA 950 ELEKTRISKE FORHOLDSREGLER ADVARSEL RISIKO FOR ELEKTRISK ST D For...
Страница 6: ...onderhouden Dit toestel staat onder GEVAARLIJKE SPANNING en mag alleen worden geopend door een daartoe opgeleide en bevoegde technicus Om het gevaar op ELEKTRISCHE SCHOKKEN te vermijden moet u het toe...
Страница 7: ...activit orageuse ATTENTION LE CORDON D ALIMENTATION SERT DE MISE HORS CIRCUIT POUR COUPER L ALIMENTATION DE L APPAREIL d branchez le cordon INSTALLATION ELECTRICITE REGLAGE DE TENSION AUTOMATIQUE Ce p...
Страница 8: ...ajohto ASENNUS S HK AUTOMAATTINEN J NNITTEENS T T m tuote s t automaattisesti mihin tahansa j nnitteeseen ohjetarrassa annettujen arvojen v lill S HK TYYPPILUOKAN 1 LAITTEET T M LAITE T YTYY MAADOITTA...
Страница 9: ...LAZIONE AUTOMATICA DELLA TENSIONE Questo prodotto regoler automaticamente la tensione ad un valore compreso nella gamma indicata sull etichetta ELETTRICIT DISPOSITIVI DI CLASSE 1 QUESTO DISPOSITIVO DE...
Страница 10: ...li tilpasset hvilken som helst str minnstilling i de omr dene som vises p etiketten ELEKTRISKE TYPE 1 KLASSE UTSTYR DETTE UTSTYRET M JORDES Str mkontakten m v re tilkoplet en korrekt jordet grunnst ps...
Страница 11: ...OLTAGEM Este produto ajustar se automaticamente a qualquer voltagem que esteja dentro dos limites indicados no r tulo EL TRICO EQUIPAMENTOS DO TIPO CLASSE 1 DEVE SER FEITA LIGA O DE FIO TERRA PARA EST...
Страница 12: ...producto se ajustar autom ticamente a cualquier tensi n entre los valores m ximos y m nimos indicados en la etiqueta ELECTRICO EQUIPO DEL TIPO CLASE 1 ESTE EQUIPO TIENE QUE TENER CONEXION A TIERRA El...
Страница 13: ...la sp nningar inom omf nget som indikeras p produktens m rkning ELEKTRISKT TYP KLASS 1 UTRUSTNING DENNA UTRUSTNING M STE VARA JORDAD N tkabeln m ste vara ansluten till ett ordentligt jordat uttag Ett...
Страница 14: ......
Страница 15: ...in Board Services xix Internet Mail xix CompuServe Forum xix World Wide Web xix Chapter 1 Overview 1 Features 2 Mode of Operation 3 Status LEDs 3 Configuration Options 5 Chapter 2 Installation 7 Proce...
Страница 16: ...cal Characteristics 16 Electrical and Mechanical Features 16 Standards 17 Appendix B Glossary 19 Appendix C Technical Support Fax Order 25 Appendix D CentreCOM AT 810SL Manual Feedback 27 Appendix E W...
Страница 17: ...rocedures LED Status Indicators and cascading Chapter 3 Operation describes conventional installation procedures LED Status Indicators and cascading Appendix A Technical Specifications includes inform...
Страница 18: ...mail via the Internet CompuServe forum When you contact Technical Support you should have the following information available Serial number of the AT 810SL fanout Power up test codes if any Diagnosti...
Страница 19: ...current user It then provides instructions about the features and functions that are available This is followed by a list and description of all available technical notes and files that can be downlo...
Страница 20: ......
Страница 21: ...s or as a concentrator grouping multiple devices onto a single tap within an Ethernet network Figure 1 shows the front panel of an AT 810SL Figure 1 AT 810SL Front Panel Additionally if you cascade mu...
Страница 22: ...ded by automatic Jabber functionality for each port Jabber protection inserts an idle state for packets over 7 ms but less than 20 ms in length Signal Quality Error SQE also referred to as Collision o...
Страница 23: ...vely you can fit an Allied Telesyn 802 3 fiber optic transceiver into this station AUI port if desired In Remote mode the AT 810SL can also either link multiple users to the backbone or cascade users...
Страница 24: ...ny of the eight transceiver ports Figure 3 Front Panel LEDs Redundant LEDs are located on the back panel of the AT 810SL These LEDs indicate the application of power for each Transceiver Port as well...
Страница 25: ...dent network with up to eight DTEs clients Additional stations can be attached to an Ethernet coaxial cable segment which may have limited taps MAUs available When numerous stations are in close proxi...
Страница 26: ......
Страница 27: ...vent damage from overheated components Remote Mode operation may require an ATI CentreCOM 100 200 150 250 270 or 470 Series external transceivers Contact your supplier for the appropriate MAU Procedur...
Страница 28: ...source with a line frequency of 50 60 Hz The unit is equipped with an IEC 320 CEE 22 standard power input connector on the back panel One end of the power cord should have a receptacle to fit this typ...
Страница 29: ...t connector are located on the back panel This is shown in Figure 5 Figure 5 Port Station Connector s Note All AT 810SL screws and mounting hardware use International Standard metric threads Do not at...
Страница 30: ...peration You have the option to place the SQE Test slide switch either ON or OFF depending on your application If ON it means that the SQE Test is provided to any DTE or workstation that is connected...
Страница 31: ...Station Port indicators When illuminated Station Port LEDs indicate system status activity as follows On Line Mode Selection is Remote for configuration status only Transmit data is being received by...
Страница 32: ...et to its associated DTE Only one LED is required to represent this function as all of the Transceiver Ports are effectively parallel for this function Collision A Collision or SQE has occurred on or...
Страница 33: ...r connected to other segments through an optional ATI CentreCOM transceiver The following figure illustrates eight CentreCOM Multiport Transceiver Fanouts cascading to provide up to 64 DTE workstation...
Страница 34: ......
Страница 35: ...to 120 VAC 50 60 Hz 0 25A 200 to 240 VAC 50 60 Hz 0 25A Transmit Static delay 150 ns typical 250 ns worst Bit loss 2 bits Physical Characteristics Dimensions 43 2 cm x 25 2 cm x 4 6 cm Weight 2 1 kg...
Страница 36: ...80 non condensing Operating altitude Up to 10 000 ft Desktop mounting 4 ea adhesive plastic feet attached to the bottom of the hub Electrical and Mechanical Features Network Ports 8 10Base5 15 Pin ma...
Страница 37: ...AT 810SL Multiport Transceiver Fanout User Manual 17 Standards Safety UL1950 CSA22 2 NO 950 TUV and EN60950 Emission FCC Class A EN55022 Class B Immunity EN50082 1...
Страница 38: ......
Страница 39: ...nnection This concentration of UTP ports is then broken out for connection to a punch down block inside a building s wiring closet 50 pin Telco connections provide a very clean uncluttered interface t...
Страница 40: ...ission system CROSSOVER Wiring used when connecting a 10Base T MAU to another 10Base T MAU or a 10Base T hub to another 10Base T hub For example one 10Base T MAU has the TD pair on the same pins as an...
Страница 41: ...up protects the medium from being overrun with data packets from a possibly defective device JAM This is a term used to describe the collision reinforcement signal output by the repeater to all ports...
Страница 42: ...wire for data and voice applications REPEATER A device used to extend the length topology or interconnectivity of the physical medium beyond that imposed by a single segment up to the maximum allowabl...
Страница 43: ...signals over long distances throughout a cable system UNSHIELDED TWISTED PAIR UTP A cable used in 10Base T and 100Base T wiring that consists of at least two twisted pairs of 22 to 26 AWG wire The pai...
Страница 44: ......
Страница 45: ...______________________________ Conditions List the steps that led up to the problem ___________________________ ______________________________________________________________________ _________________...
Страница 46: ......
Страница 47: ...__________________________ I would like the following more developed _____________________________________ ______________________________________________________________________ ______________________...
Страница 48: ......
Страница 49: ...Greece Turkey Israel 39 2 416047 39 2 419282 Japan 81 3 3443 5640 81 3 3443 2443 North America United States Canada Mexico Central America South America 1 800 428 4835 1 206 481 3790 United Kingdom Un...
Страница 50: ...United States Scottsdale AZ Tel 602 423 7087 Fax 602 423 7088 Los Angeles CA Tel 310 412 8684 Fax 310 546 3323 Mission Viejo CA Tel 714 699 0628 Fax 714 699 0276 San Diego CA Tel 619 279 3899 Fax 619...
Страница 51: ...rve xix internet mail xix manual feedback 27 phone numbers xviii technical support fax order 25 world wide web xix D document conventions xviii E electrical and mechanical features 16 I incident summa...
Страница 52: ......