![Allied Telesis AT-MMC6005 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/allied-telesis/at-mmc6005/at-mmc6005_installation-manual_2902194049.webp)
49
Chapter 3
Troubleshooting
This chapter contains information on how to troubleshoot the
AT-MMC6000 Series media converters in the event a problem occurs.
Note
For further assistance, please contact Allied Telesis Technical
Support at
Problem 1:
The SYS LED on the media converter is off.
Solutions:
The unit is not receiving power. Try the following:
Verify that the power cord is securely connected to the power
source and to the DC connector on the back panel of the media
converter.
Verify that the power outlet has power by connecting another
device to it.
Try using another power adapter of the same type that came with
your media converter.
Verify that the voltage from the power source is within the required
levels for your region.
Solution:
An internal component on the unit is damaged or not working
properly. Try power cycling the unit. If power cycling does not clear the
fault, return the unit to Allied Telesis.
Problem 2:
The twisted-pair port on the media converter is connected to
an end node, but the port’s COPPER P1 L/A LED is off.
Solutions:
The port is unable to establish a link to an end node. Try the
following:
Verify that the end node connected to the twisted-pair port is
powered on and is operating properly.