Chapter 2: Installation
44
Note
If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than
the room ambient temperature. Therefore, consideration should be
given to installing the equipment in an environment compatible with
the manufacturer’s maximum rated ambient temperature (Tmra).
E35
Caution
Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not
compromised.
E36
Warning
Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than
direct connections to the branch circuits (e.g., use of power strips).
E37
Warning
To reduce the risk of electric shock, the PoE ports on this product
must not connect to cabling that is routed outside the building where
this device is located.
E40
Warning
An SFP transceiver can be damaged by static electricity. Be sure to
observe all standard electrostatic discharge (ESD) precautions,
such as wearing an antistatic wrist strap, to avoid damaging the
transceiver.
E86
Caution
The switch does not forward network traffic during the reboot
process. Some network traffic may be lost.
E113
Wall-Mount Orientation Installation Requirements
The AT-GS950/28PS unit must be installed with the RJ45 connectors
facing up (toward the ceiling) or down (toward the floor) and cannot be
installed with the RJ45 connectors facing right or left. See Figure 23 on
page 45.