background image

A5 Installation and Safety Guide Cover

AT-8600 Series Switch
Installation and Safety Guide

AT-8624T/2M
AT-8624PoE
AT-8648T/2SP

Содержание AT-8624T/2M, AT-8624PoE

Страница 1: ...AT 8600 Series Switch Installation and Safety Guide AT 8624T 2M AT 8624PoE AT 8648T 2SP ...

Страница 2: ...AT 8600 Series Installation Safety Guide AT 8624T 2M AT 8624PoE AT 8648T 2SP Download the complete document set from www alliedtelesis com support software ...

Страница 3: ... written notice The information provided herein is subject to change without notice In no event shall Allied Telesis Inc be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein even if Allied Telesis Inc has been advised of known or should have known the ...

Страница 4: ...Site 5 Installing the Switch 6 Connecting the Switch 10 Checking LEDs 13 Obtaining Documentation and Resources 18 Standards 19 Safety 20 Sicherheit 21 Sikkerhed 23 Veiligheid 24 Sécurité 25 Turvallisuus 26 Norme di Sicurezza 28 Sikkerhet 29 Segurança 30 Seguridad 32 Säkerhet 33 EC Declaration of Conformity 35 ...

Страница 5: ...aged or missing One AC power cord One power cord retaining clip One serial cable for connecting the switch to a terminal or PC One 19 inch rack mount kit One AT 8600 Series Installation Safety Guide which includes statutory and safety information One warranty card Preinstalled AT A65 expansion modules You can order the AT 8624T 2M or AT 8624PoE switches with two AT A65 expansion modules included T...

Страница 6: ... and earthed grounded power supply source preferably dedicated and filtered Cabling must not be exposed to sources of electrical noise such as radio transmitters broadband amplifiers power lines electric motors and fluorescent fixtures Switch ports are suitable for connection to intra building or non exposed cabling is required Related network devices can be connected to the switch but cannot exce...

Страница 7: ...of the PSU you need an appropriate DC power source DC supply cable ring connectors and a crimp tool Choose a suitable operating location You can install the switch either in a 19 inch rack on a flat bench or against a wall Follow the guidelines in Selecting a Site on page 5 to choose a location To ensure rack mounted installations are earthed for compatibility with Network Equipment Building Syste...

Страница 8: ...ready powered on you must restart the switch before you can use the module 2 Place the switch in its operating location If installing the switch in a rack Remove the rubber feet on the bottom of the switch with a flat head screwdriver Attach the two rack mounting brackets to the switch with the screws provided in the rack mount kit 3 Mount the switch in the rack using rack mount screws Note that t...

Страница 9: ...al main power supply that functions from100 240 VAC and 50 60 Hz Specific power supply requirements for the model are on the rear or underside of the switch If the supply is outside the acceptable range the switch may not operate or may be damaged 6 Apply AC power to the switch Plug the power cord into the AC power connector This is on the switch s rear panel as shown in the below figures Figure 1...

Страница 10: ...ch cable connection is secure The switch can now process basic Layer 2 switching functions 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 FAULT RPS MASTER PWR MODE 1 3 5 7 9 11 2 4 6 8 10 12 13 15 17 19 21 23 14 16 18 20 22 24 STATUS 26 RS 232 TERMINAL PORT COL HALF DUP FULL DUP ACT 100 LINK 10 LINK ACT PD ON MAX CURRENT PD ERR AT 8624POE Layer 3 Fast Ethernet Switch 25 SFP 50 STAT...

Страница 11: ...eters on your terminal or terminal emulation program to Bit rate 9600 Data bits 8 Parity None Stop bits 1 Flow control None 3 Log in After the switch has booted the login prompt appears If it does not appear press the Enter key several times When the switch starts for the first time it automatically creates an account with manager privileges The account has the login name manager and the password ...

Страница 12: ...gh letters to uniquely match the desired one press the Tab key 7 Save the configuration Save your configuration to a new file by using the command create config filename cfg Then set the switch to load this file when it restarts by using the command set config filename cfg For information about configuring the software see the AT 8600 Series Software Reference Using the GUI to configure the AT 862...

Страница 13: ...nable IP enable ip 5 Assign the vlan1 interface an IP address in the same subnet as the PC add ip interface vlan1 ip ipaddress mask mask 6 Save the configuration and set the switch to use it on bootup create config your name cfg set config your name cfg 7 On the PC s web browser bypass the HTTP proxy server if necessary 8 Point your Web browser at IP address for vlan1 9 At the login prompt enter t...

Страница 14: ... fan has failed 3 flashes The main PSU has failed and the RPS is now providing power 4 flashes The RPS Monitor is set to ON and the RPS is not functioning either because it has failed or has been switched off 5 flashes The RPS Monitor is set to ON but the RPS is not connected 7 flashes For the AT 8624T 2M and AT 8624PoE switches An expansion module has been inserted or removed while the switch is ...

Страница 15: ... COL Off No data collisions are occurring on the port Flashing Green Data collisions are occurring on the port Mode 100 Off The port is operating at 10 Mbps Green The port is operating at 100 Mbps Mode FULL Off The port is operating in half duplex mode Green The port is operating in full duplex mode Mode ACT Off There is no activity on the port Flashing Green There is activity on the port It is tr...

Страница 16: ...Mode LEDs Bottom LED Off Either DC Mode or PoE Mode D C Mode Off There is no link between the port and the end node Green The port is operating in full duplex mode Red The port is operating in half duplex mode Flashing Red The port is operating in half duplex mode and data collisions are occurring on the port PoE Mode Off There is no powered device detected Green The end node is a powered device a...

Страница 17: ... and the end node Mode COL Off No data collisions are occurring on the port Flashing Green Data collisions are occurring on the port Mode SPD Off The port is operating at 10 Mbps Green The port is operating at 100 Mbps Mode FDX Off The port is operating in half duplex mode Green The port is operating in full duplex mode Mode ACT Off There is no activity on the port Flashing Green There is activity...

Страница 18: ... port and the end node Mode COL Off No data collisions are occurring on the port Flashing Green Data collisions are occurring on the port Mode SPD Off The port is operating at 10 100 Mbps Green The port is operating at 1000 Mbps Mode FDX Off The port is operating in half duplex mode Green The port is operating in full duplex mode Mode ACT Off There is no activity on the port Flashing Green There i...

Страница 19: ...port software You need Adobe Acrobat Reader software to view search or print these documents You can download it from www adobe com Other resources How To Notes describe a range of standard Allied Telesis solutions and include technical tips and guides to configuring specific hardware and software features You can download the latest How To Notes from www alliedtelesis com resources literature how...

Страница 20: ...esigned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmf...

Страница 21: ...ED AS A DISCONNECTION DEVICE TO DE ENERGIZE EQUIPMENT disconnect the power cord ELECTRICAL TYPE CLASS 1 EQUIPMENT THIS EQUIPMENT MUST BE EARTHED Power plug must be connected to a properly wired earth ground socket outlet An improperly wired socket outlet could place hazardous voltages on accessible metal parts PLUGGABLE EQUIPMENT the socket outlet shall be installed near the equipment and shall be...

Страница 22: ...uipment must be contained in the same building including the interconnected equipment s associated LAN connections CAUTION The surface mount fuses F1 to F24 on the Power over Ethernet daughterboard in the AT 8624PoE switch are 60V max 2A fuses These fuses are not field replaceable and should only be serviced by a trained Allied Telesis service technician Sicherheit WARNUNG Bei Verwendung zu Hause ...

Страница 23: ...iner Umgebungstemperatur von nicht mehr als 40 C entworfen NETZSICHERUNG Bei der Installation muß der auf dem Typenschild angezeigte Nennwert des Gerätes für den Anschluß an das Netz beachtet werden VORSICHT RAHMENEINBAU Die Geräte müssen so in den Rahmen montiert werden daß keine Gefahren durch unebenen inbau des Rahmens verursacht werden Lithium Batterie Sollte nur von einem geschulten qualifizi...

Страница 24: ...ARATET AFBRYDES tages ledningen ud af stikket ELEKTRISK KLASSE 1 UDSTYR DETTE UDSTYR KRÆVER JORDFORBINDELSE Stikket skal være forbundet med en korrekt installeret jordforbunden stikkontakt En ukorrekt installeret stikkontakt kan sætte livsfarlig spænding til tilgængelige metaldele UDSTYR TIL STIKKONTAKT stikkontakten bør installeres nær ved udstyret og skal være lettilgængelig ADVARSEL Ventilation...

Страница 25: ...inde ELEKTRISCHE schokken te voorkomen Binnenin bevinden zich geen onderdelen die door de gebruiker onderhouden kunnen worden Dit toestel staat onder GEVAARLIJKE SPANNING en mag alleen worden geopend door een daartoe opgeleide en bevoegde technicus GEVAAR VOOR BLIKSEMINSLAG GEVAAR NIET aan toestellen of KABELS WERKEN bij BLIKSEM WAARSCHUWING HET TOESTEL WORDT UITGESCHAKELD DOOR DE STROOMKABEL TE O...

Страница 26: ...jkwaardig door de fabrikant aanbevolen type ALLE LANDEN het toestel installeren overeenkomstig de lokale en nationale elektrische voorschriften Sécurité MISE EN GARDE dans un environnement domestique ce produit peut provoquer des interférences radioélectriques Auquel cas l utilisateur devra prendre les mesures adéquates ATTENTION Producit laser di classe 1 ATTENTION Ne pas fixer le faisceau des ye...

Страница 27: ... en compte la somme des puissances indiquées sur les étiquettes au moment de connecter le matériel à une source de courant alternatif ATTENTION RÉPARTITION DE LA CHARGE MÉCANIQUE Le montage du matériel dans le bâti doit être effectué de telle manière que la répartition de la charge mécanique ne pose aucun danger Pile en Lithium Doit uniquement être remplacée par un technicien dûment qualifié ATTEN...

Страница 28: ...ia on asennettava laitteen lähelle ja siihen on oltava esteetön pääsy HUOMAUTUS Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys ympäröivään huoneilmaan jotta ilmanvaihto tapahtuisi KÄYTTÖLÄMPÖTILA Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle 40 C SÄHKÖ VAIHTORVIRTASÄHKÖPIIRIN YLIKUORMITUS Tuotetta asennettaessa on otettava huomioon osien nimikilvissä osoitettu ...

Страница 29: ...GLIERE LA CORRENTE AL DISPOSITIVO staccare il cavo di alimentazione ELETTRICITÀ DISPOSITIVI DI CLASSE 1 QUESTO DISPOSITIVO DEVE AVERE LA MESSA A TERRA La spina deve essere inserita in una presa di corrente specificamente dotata di messa a terra Una presa non cablata in maniera corretta rischia di scaricare una tensione pericolosa su parti metalliche accessibili APPARECCHIATURA COLLEGABILE la presa...

Страница 30: ...uktet forårsake radioforstyrrelse Hvis dette skjer må brukeren ta de nødvendige forholdsregler ADVARSEL Laserprodukt av klasse 1 ADVARSAL Stirr ikke på strålen ELEKTRISITET ADVARSEL FARE FOR ELEKTRISK SJOKK For å unngå ELEKTRISK sjokk må dekslet ikke tas av Det finnes ingen deler som brukeren kan reparere på innsiden Denne enheten inneholder FARLIGE SPENNINGER og må kun åpnes av en faglig kvalifis...

Страница 31: ...ikanten Batteriene må kasseres i samsvar med fabrikantens instruksjoner ALLE LAND Produktet må installeres i samsvar med de lokale og nasjonale elektriske koder Segurança AVISO Num ambiente doméstico este produto pode causar interferência na radiorrecepção e neste caso pode ser necessário que o utente tome as medidas adequadas AVISO Produto laser de classe 1 AVISO Não olhe fixamente para o raio AV...

Страница 32: ...peratura ambiente máxima de 40 graus centígrados ELÉTRICO SOBRECARGA DA REDE DE CORRENTE ALTERNADA AC Antes de instalar o produto verifique o efeito cumulativo da conexão de diversos aparelhos àrede de corrente alternada através das etiquetas que indicam potência ou amperagem CUIDADO CARREGAMENTO O equipamento deverá ser montado no suporte de montagem de forma tal que não cause perigo devido a car...

Страница 33: ...SPOSITIVO DE DESCONEXION PARA DESACTIVAR EL EQUIPO desconecte el cable de alimentación ELECTRICO EQUIPO DEL TIPO CLASE 1 ESTE EQUIPO TIENE QUE TENER CONEXION A TIERRA El cable tiene que conectarse a un enchufe a tierra debidamente instalado Un enchufe que no está correctamente instalado podría ocasionar tensiones peligrosas en las partes metálicas que están expuestas EQUIPO CONECTABLE el tomacorri...

Страница 34: ...lass 1 VARNING Laserstrålning när enheten är öppen TILLKÄNNAGIVANDEN BETRÄFFANDE ELEKTRICITETSRISK RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt ta ej av locket Det finns inga delar inuti som behöver underhållas Denna apparat är under HÖGSPÄNNING och får endast öppnas av en utbildad kvalificerad tekniker FARA FÖR BLIXTNEDSLAG FARA ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER VARNI...

Страница 35: ...G MEKANISK BELASTNING Utrustningen ska installeras i chassit på så sätt att fara inte uppstår p g a ojämn belastning Litium batteri Får endast bytas av utbildade och kvalificerade tekniker VARNING Risk för explosion om felaktigt batteri används Byt endast mot samma eller likvärdig typ batteri rekommenderat av tillverkaren Kassera använda batterier i enlighet med tillverkarens instruktioner ALLA LÄ...

Страница 36: ...n Technology Equipment Immunity characteristics Limits and methods of measurement EN60950 1 2001 Incl A11 2004 Information Technology Equipment including electrical business equipment General Requirements EN60825 1 1994 Incl A1 2002 and A2 2001 Safety of Laser Products part 1 Equipment classification requirements and user s guide EN61000 3 2 2000 Incl A2 2005 Electromagnetic compatibility EMC Part...