Allied Data Technologies
31
ASCII value of the character used as the escape code. The default value is 043,
corresponding to the character '+'. If the content of the register is greater than
127, the escape code is disabled.
S3
* 013
0-127
Carriage return character
Specifies the ASCII character to be used as the carriage return character.
Carriage return indicates the end of a command line.
S4
010
0-127
Line feed character
Specifies the ASCII character to be used as the line feed character. The line feed
comes at the end of a command line after the carriage return.
S5
008
0-255
Backspace character
Specifies the ASCII character to be used as the backspace character. A value
greater than 32 disables backspace recognition.
S6
* 006
2-255
Maximum wait time for dial tone or blind dialling.
The value in this register determines the wait time for the dial tone after the
modem goes on line. If no dial tone is detected, the modem checks whether
blind dialling is set. The same wait time is used if the character ‘W’ is included in
the telephone number.
S7
* 060
0-60
Carrier timeout
This register determines how long the modem will wait for a carrier after dialling.
This time is a value in seconds.
S8
* 002
0-255
Length of the pause character
The pause character ',' can be used to insert a delay when dialling. This time is a
value in seconds.
S9
* 006
1-255
Carrier detect time
A carrier must be detected during the time entered in this register. This time is a
value expressed in 1/10 seconds. S9 must always be less than S10.
S10 * 014
1-255
Carrier lost time