No Water Flow Error
E nFLo
(No Hot or Cold Tub Fill)
Is the water turned
on?
Are fill valve inlet
screens plugged?
Yes
Turn on water.
No
Is there a fill step
programmed?
No
Clean inlet screens
and re-test.
Yes
Run Factory Test.
Yes
Add/edit a fill step
in programming.
No
Check continuity
between the following
connections During
Hot or Cold Tub Fill.
(A)
Hot Tub Fill: on AP1,
is there 24VDC
between H9-9 and
H9-13?
(B)
Cold Tub Fill: on
AP1, is there 24VDC
between H9-10 and
H9-13?
Yes
Replace AP1.
No
(A1, B1)
Ensure plugs are
attached to the
valves and re-check
voltages at the
valves. Is voltage
present at valves?
Yes
Replace AP1.
No
Replace mixing valve.
Yes
Check wiring between
valve and AP1.
Replace if needed.
No
Troubleshooting
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
71
Part No. F8677701EN
Содержание SCA030FN
Страница 2: ......
Страница 66: ...Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 66 Part No F8677701EN ...
Страница 88: ...Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 88 Part No F8677701EN ...
Страница 93: ...Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 93 Part No F8677701EN ...
Страница 103: ...Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 103 Part No F8677701EN ...
Страница 115: ...Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 115 Part No F8677701EN ...
Страница 121: ...Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 121 Part No F8677701EN ...