No Display
(A)
Is 100-120VAC or
200-240VAC present
between H1-1 & H1-2
on AP1 I/O Board?
(B )
On AP1, is the 12VDC
LED On?
Yes
Refer to No Power to
I/O Board sections.
No
(C)
On AP1, is there
12VDC between H3-4
(+) H3-5 (-)?
Yes
Replace I/O board.
No
(D)
On AP2 Front End
Control, is there
12VDC between H2-4
(+) H2-5 (-)?
Yes
Replace I/O board.
No
On AP2 Front End
Control, press keypad
to wake up the
control. Does the
control turn on?
Yes
Replace AP1 to AP2
harness.
No
Replace AP2.
Yes
Is the keypad ribbon
cable from the keypad
plugged into the
control logic board
AP2?
No
Plug in ribbon
cable.
No
Replace AP2.
Yes
Troubleshooting
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
23
Part No. F8677701EN
Содержание SCA030FN
Страница 2: ......
Страница 66: ...Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 66 Part No F8677701EN ...
Страница 88: ...Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 88 Part No F8677701EN ...
Страница 93: ...Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 93 Part No F8677701EN ...
Страница 103: ...Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 103 Part No F8677701EN ...
Страница 115: ...Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 115 Part No F8677701EN ...
Страница 121: ...Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 121 Part No F8677701EN ...