background image

Front View (Without Closet Door)

 

DRY2663N_SVG

B

A

A

 

Side View (Closet Door)

 

DRY2664N_SVG

1

C

A

D

E

H

3

 

Front View (Closet Door)

 

DRY2637N_SVG

F

F

2 (G)

 

1.  

Closet Door

2.  

Centered Air Openings (G) (2 Openings minimum)

3.  

Outer Wall of Enclosure

Figure 3

Installation

  8

©

 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT

  Part No. 510963R7

Содержание Dryers

Страница 1: ...Instructions for Dryers Original Instructions Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine www alliancelaundry com Part No 510963R7 November 2014 ...

Страница 2: ......

Страница 3: ...uctions and local codes DO NOT install a clothes dryer with flexible plas tic venting materials If flexible metal foil type duct is installed it must be of a specific type identified by the appliance manufacturer as suita ble for use with clothes dryers Refer to section on connecting exhaust system Flexible venting materials are known to collapse be easily crush ed and trap lint These conditions w...

Страница 4: ...g 14 Connecting Power Cord with Four Wire Plug 16 Reverse Door if Desired 17 Wipe Out Inside of Dryer 19 Plug In the Dryer 19 Electric Dryer 19 Gas Dryers 19 Grounding Information 20 Recheck Steps 20 Check Heat Source 20 Electric Dryers 20 Gas Dryers 20 Installer Checklist 22 Copyright 2014 Alliance Laundry Systems LLC All rights reserved No part of the contents of this book may be reproduced or t...

Страница 5: ...mm E 43 in 1092 mm F 15 4 in 391 mm G 15 44 in 392 mm H 26 9 in 683 mm I 4 0 in 102 mm J 0 4 in 11 mm K 4 5 in 114 mm L 28 in 711 mm M 23 5 in 597 mm NOTE Exhaust openings are 4 inch 102 mm metal ducting With leveling legs turned into base Dimensions Part No 510963R7 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 5 ...

Страница 6: ...43 in 1092 mm F 15 4 in 391 mm G 15 44 in 392 mm H 2 8 in 70 mm I 2 3 in 60 mm J 26 9 in 683 mm K 4 in 102 mm L 0 4 in 11 mm M 4 5 in 114 mm N 28 in 711 mm O 23 5 in 597 mm NOTE Exhaust openings are 4 inch 102 mm metal ducting With leveling legs turned into base Dimensions 6 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Part No 510963R7 ...

Страница 7: ...Select a location with a solid floor Dryers installed in resi dential garages must be elevated 18 inches 457 mm above the floor No other fuel burning appliance should be installed in the same closet with the dryer The dryer must not be installed or stored in an area where it will be exposed to water and or weather Leveling legs can be adjusted from inside the dryer with 1 4 in driver All four legs...

Страница 8: ...t Door DRY2664N_SVG 1 C A D E H 3 Front View Closet Door DRY2637N_SVG F F 2 G 1 Closet Door 2 Centered Air Openings G 2 Openings minimum 3 Outer Wall of Enclosure Figure 3 Installation 8 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Part No 510963R7 ...

Страница 9: ... IMPORTANT In mobile home installations gas dryers MUST be permanently attached to the floor at the time of installation Order No 526P3 Dryer Installation Kit available at extra cost for a manufactured mobile home installation Follow the instructions supplied with the kit Connect Dryer Exhaust System WARNING To reduce the risk of fire and the accumulation of combustion gases DO NOT exhaust dryer a...

Страница 10: ...iltration rates should be equipped with an air exchanger that can accommo date on demand make up air needs in the laundry room These devices can be obtained through your building contractor or building material suppliers Static pressure in exhaust duct should not be greater than 0 6 inches water column 1 5 cm water column measured with manometer placed on exhaust duct two feet 610 mm from dryer ch...

Страница 11: ... 8 m 1 55 feet 16 8 m 47 feet 14 3 m 2 47 feet 14 3 m 41 feet 12 5 m 3 36 feet 11 0 m 30 feet 9 1 m 4 28 feet 8 5 m 22 feet 6 7 m Table 2 NOTE Deduct 6 feet 1 8 m for each additional elbow NOTE The maximum length of a 4 in 102 mm diame ter flexible metal duct must not exceed 7 87 ft 2 4 m as required to meet UL2158 clause 7 3 2 A Installation Part No 510963R7 Copyright Alliance Laundry Systems LLC...

Страница 12: ...in the ab sence of local codes and ordinances with the latest edition of the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the CAN CSA B149 1 Natural Gas and Propane Installation Code Natural Gas 1000 Btu ft3 37 3 MJ m3 service must be supplied at minimum 5 0 inch 127 mm water column pressure to maxi mum 10 5 inch 267 mm water column pressure For proper operation at altitudes above 3000 feet 915 m...

Страница 13: ...000 2440 56 0 0465 1 18 503786 Table 4 Connect Electrical Plug Electric Dryer Only Dryer requires 120 240 Volt or 120 208 Volt 60 Hertz 3 wire electrical supply Refer to serial plate for specific electrical re quirements IMPORTANT Use only a new U L listed No 0 copper wire only three conductor power supply cord kit rated 240 Volts minimum 30 Amperes and labeled as suita ble for use in a clothes dr...

Страница 14: ...d dryer terminal block IS NOT supplied with dryer Type of power cord and gauge of wire must conform to local codes Connecting Power Cord with Three Wire Plug NOTE Four wire cord is required for new branch cir cuit installations mobile homes or where codes do not permit grounding through neutral NOTE The power cord is NOT supplied with the elec tric dryer Type of power cord and gauge of wire must c...

Страница 15: ...vice Entrance Switch Box Refer to NOTE above 8 30 Ampere Fuses or Circuit Breaker 9 Neutral Wire 10 Metallic or Non Metallic Sheathed Cable Copper Wire Only 11 Power Cord Not supplied with dryer 12 Neutral 13 Terminal Block in Dryer 14 Intermediate Shut Off Box may or may not be fused 15 Direct Connection 16 Power Cord Connection Figure 6 1 Disconnect power to dryer 2 Remove access cover from rear...

Страница 16: ... earth ground pin of the plug and the green screw on the back of the cabinet 8 Reinstall access cover and screw Connecting Power Cord with Four Wire Plug NOTE Four wire cord is required for new branch cir cuit installations mobile homes or where codes do not permit grounding through neutral DRY2016N_SVG 7 7 7 7 6 3 2 1 4 5 1 Typical Four Wire Receptacle 2 Power Cord Not Supplied with Dryer 3 Strai...

Страница 17: ...Neutral terminal NOTE When installing the white wire loop the free eyelet end of the earth ground to neutral wire re moved in Step 4 and attach along with the white wire to the neutral center terminal on the terminal block 8 Tighten all screws firmly IMPORTANT Failure to tighten these screws firmly may result in wire failure at the terminal block 9 Check the continuity of the ground connection bef...

Страница 18: ...e door strike from door liner and reinstall on opposite side DRY1917N_SVG Figure 20 6 Insert liner under flange on bottom of door then push top of door liner into place DRY1918N_SVG B A Figure 21 7 Reinstall nine screws removed in Step 2 DRY1919N_SVG Figure 22 8 Using screwdriver remove two door plugs and reinstall on opposite side of door opening Installation 18 Copyright Alliance Laundry Systems...

Страница 19: ...t edition of the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 and such local regulations as might apply It is the customer s responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer W521 When plugging in the dryer Do not overload circuits Do not use an adapter Do not use an e...

Страница 20: ...e outlet have a proper outlet installed by a qualified electrician NOTE Have a qualified electrician check the polarity of the wall receptacle If a voltage reading is measured other than that listed on the dryer s nameplate the qualified electrician should correct the problem Do not operate other appliances on the same circuit when this ap pliance is operating WARNING To reduce the risk of an elec...

Страница 21: ...me indicates too much air Adjust the air shutter as follows a Loosen the air shutter lockscrew b Turn the air shutter to the left to get a luminous yellow tipped flame then turn it back slowly to the right to obtain a steady soft blue flame c After the air shutter is adjusted for proper flame tighten the air shutter lockscrew securely 5 Reinstall the lower front panel WARNING For personal safety l...

Страница 22: ...c D275I_SVG1 Gas D254I_SVG CHECK CHECK 3 GAS ONLY Connect Gas Sup ply Pipe Check for Gas Leaks D258I_SVG1 8 Recheck Steps CHECK CHECK 4 ELECTRIC ONLY Connect Electrical Cord D699I_SVG1 9 Check Heat Source D702I_SVG1 CHECK CHECK 5 Reverse Door if De sired D675I_SVG1 CHECK Refer to the manual for more detailed information Installer Checklist Part No 510963R7 Copyright Alliance Laundry Systems LLC DO...