58
70269301
Section 6 Adjustments
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 22
T041IE3A
AIR FLOW
SWITCH
COUNTERWEIGHT
SPRING
CLIP
DISC
SWITCH
LEVER
MOUNTING
BRACKET
REAR
PANEL OF
TUMBLER
AIR FLOW
SWITCH
VANE
LEVER
ARM
DISC
COUNTERWEIGHT
SWITCH
LEVER
SWITCH
ADJUSTING
SCREWS
SCREW
SPRING
CLIP