Clothes Do Not Dry in Dryer
Does heater assembly
not heat or burner
not ignite?
Is there too much
water in articles
being dried?
No
Refer to Dryer
Heating Assembly Does
Not Heat or Burner
Does Not Ignite
paragraph.
Yes
Is laundry load too
large?
No
Remove excess water.
Yes
Is laundry load too
small?
No
Remove part of load.
A normal washer load
is a normal dryer
load. Maximum load:
Dryer cylinder one
half full of wet
clothes.
Yes
Is there excessive
lint on lint filter?
No
Add one or two bath
towels to load.
Yes
Timer models: Is heat
selector switch or
timer inoperative?
No
Clean lint filter.
Yes
Electronic control
models: Is cycle
selector or control
inoperative?
No
Test and replace
switch or timer if
inoperative.
Yes
Is exhaust system
improper or
inadequate?
No
Test and replace
cycle selector or
control if
inoperative.
Yes
Does heater assembly
or burner shut off
prematurely?
No
Refer to Installation
Instructions
(supplied with unit)
for exhaust
requirements.
Yes
Gas Models: Is gas
line pressure too
high or too low?
No
Refer to Dryer Heater
Assembly or Burner
Shuts Off Prematurely
paragraph.
Yes
If Natural Gas line
pressure to dryer
exceeds 8 inch water
column pressure, or
is lower than 4 inch
water column, ask Gas
Company to correct.
Yes
Continued on
next page
Troubleshooting Flowcharts
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
30
Part No. D515517ENR3
Содержание ZDE3SRGS173CW01
Страница 2: ......