ELECTRICAL SPECIFICATIONS
MODEL
CODE
FULL LOAD AMPS - MODELS WITH
COLD AND HOT WATER FILL
FULL LOAD AMPS - MODELS WITH
ELECTRIC HEATING (kW)
[kg / lb / L]
24
36
45
54
26 / 57 / 265
Q
16
68
-
-
-
P
7.5
38
-
-
-
N
7.5
37
-
-
-
33 / 73 / 332
Q
16.5
-
70
-
-
P
8
-
59
-
-
N
8
-
54
-
-
44 / 97 / 442
Q
20
-
-
127
-
P
12
-
-
73
-
N
12
-
-
67
-
66 / 146 / 663
Q
21
-
-
-
148
P
13
-
-
-
89
N
13
-
-
-
79
Table 8
Adaptation of conductor ends of supply cable
1. Protection conductor
5. Neutral conductor
2. Phase conductor
6. Molded tube
3. Phase conductor
7. The stripped length of con-
ductors
4. Phase conductor
Figure 21
Connection of main power inlet
1.
Main switch
2.
Cable bushing
3.
Cable bushing nut
4.
Sag of inlet cable
Figure 22
WASHER PROTECTIVE EARTH CONNECTION
(GROUND) AND EQUIPOTENTIAL BONDING
Independent of the supply cable, the washer must be connected to
the laundry protective earth system with a separate conductor.
The protection conductor, enabling this connection, is not includ-
ed with the washer. If there are other washers/appliances with ex-
INSTALLATION
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
49