Power supply protection device nominal current (US)
Min. phase conductor
section, AWG [mm
2
]
Min. protection conduc-
tor section, AWG [mm
2
]
Automatic circuit break-
ers
Fuses
100A
80A
3 [25]
5 [16]
125A
100A
2 [35]
3 [25]
160A
125A
- [50]
2 [35]
200A
160A
- [70]
- [50]
250A
200A
- [95]
- [70]
300A
250A
- [120]
- [95]
Table 6
ELECTRICAL SPECIFICATIONS
MODEL
CODE
VOLTAGE
CYCLE
PHASE
WIRE
[kg / lb / L]
26 / 57 / 265
Q
200-240
50-60
3
3 (L1, L2, L3)
P
380-415
50-60
3
3 (L1, L2, L3)
N
440-480
50-60
3
3 (L1, L2, L3)
33 / 73 / 332
Q
200-240
50-60
3
3 (L1, L2, L3)
P
380-415
50-60
3
3 (L1, L2, L3)
N
440-480
50-60
3
3 (L1, L2, L3)
44 / 97 / 442
Q
200-240
50-60
3
3 (L1, L2, L3)
P
380-415
50-60
3
3 (L1, L2, L3)
N
440-480
50-60
3
3 (L1, L2, L3)
66 / 146 / 663
Q
200-240
50-60
3
3 (L1, L2, L3)
P
380-415
50-60
3
3 (L1, L2, L3)
N
440-480
50-60
3
3 (L1, L2, L3)
Table 7
INSTALLATION
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
48
Part No. D1612ENR3