505033
37
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
42. MOTOR AND EXHAUST ASSEMBLY
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
access panel. See Figure 6.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. See
Figure 13.
c. Open loading door and remove filter. See
d. Remove screws holding lower air duct to upper
air duct and remove lower air duct. See
Figure 19.
IMPORTANT: When reassembling, be sure seal on
exhaust fan cover makes airtight seal on flange of
duct. See Figure 18. If the seal is installed
improperly, the airflow through the exhaust system
will be restricted which can adversely affect dryer
performance.
e. Disconnect wires from thermostat (and heater,
if present) then disconnect ground wire screw.
See Figure 20
NOTE: Refer to wiring diagram when rewiring
thermostat and heater.
f. Remove cylinder belt from idler and motor
pulleys. See Figure 21.
g. Disengage motor wire harness terminal block
from motor switch by pressing in on the
movable locking tabs (located on each end of
the terminal block) and pulling away from
motor. See Figures 22 and 24.
h. Remove two screws holding motor mounting
bracket to dryer base. See Figure 20.
To reduce the risk of serious injury or death
by carbon monoxide and other gases in gas
dryers, carefully read and follow all
instructions given in this section.
W005
WARNING
Figure 21
BELT
IDLER
PULLEY
IDLER
LEVER
EXHAUST
DUCT
D247SE1A
CORRECT
WAY
BELT ON WRONG SIDE
OF IDLER LEVER
BELT
IDLER
PULLEY
IDLER
LEVER
EXHAUST
DUCT
D248SE1A
INCORRECT
WAY