505033
19
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
Section 5
Service Procedures
IMPORTANT: When reference to direction (right
or left) is made in this manual, it is from the
operator’s position facing the front of the dryer.
19. CONTROL HOOD ASSEMBLY
(Figure 5)
a. Remove three screws holding control hood
assembly to control hood rear panel.
b. Rotate assembly forward to access inner
wiring.
c. Disconnect wiring from inner components and
carefully remove components from control
hood assembly.
NOTE: Refer to wiring diagram when rewiring
component parts.
d. Rotate control hood assembly forward and lift
to free assembly from hold-down clips.
20. CONTROL HOOD END CAPS
(Figure 5)
a. Remove three screws holding control hood
assembly to control hood rear panel.
b. Rotate assembly forward to access inner
wiring.
c. Disconnect wiring from inner components and
carefully remove components from control
hood assembly.
NOTE: Refer to wiring diagram when rewiring
component parts.
d. Remove two screws holding end cap to end of
support control panel.
e. Carefully pry end cap from support control
panel.
NOTE: To re-assemble, reverse the steps.