Section 3 Troubleshooting (NetMaster and MDC Models)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
20. WASHER OVERFLOWS
Washer Overflows
Is there
220-240 VAC
(or 120 VAC)*
to the over level terminal
on pressure switch
to neutral?
Yes
No
Replace
inoperative
pressure switch.
Is there
220-240 VAC
(or 120 VAC)*
across the coil of either
the hot or cold water
solenoid?
Yes
No
Check for
improper wiring
and replace
inoperative
pressure switch
if necessary.
Replace
inoperative water
valve.
(1)
(2)
FLW1699S
*Refer to machine serial plate for correct voltage.