Factory Setting
Description of Factory Parameters Set-
ting
WARNING
THESE PARAMETERS ARE PRESET IN PRODUC-
TION PLANT AND THERE IS GENERALLY NO NEED
TO CHANGE THEM. INCORRECT SETTING CAN
CAUSE DEFECT IN MACHINE FUNCTIONS.
C164
If certain linen types are being ironed most frequently (for exam-
ple, bed sheets or tablecloths), parameters can be adjusted to ach-
ieve better folding results. To access the factory settings, press
the "2" key from the main menu after starting the machine:
1: Start Ironing
2: Machine Settings
Factory settings are password protected. After pressing the key "
K
), the request for password is dis-
played:
Protected Menus.
Enter code:
To leave this selection, press the "
P
" key.
Now enter the password
„3820“
and confirm by pressing the "
I
"
key. The display will read:
P R I M U S
Factory Settings
Now set the individual parameters:
1. Length of impulse:
[Input: 0.001 mm ]
Pulse length:
It is not advisable to change this parameter. It affects meas-
urement of the fold length.
2. Delay of clamps
[Input: x10ms ]
Clamps delay:
It defines the time period between the moment of pressing the
linen on the feeding table by pad rollers, and opening the
clamps. Suitable time period is 250-400 ms, which is dis-
played as value 25-40.
3. Setting first fold:
[Input: pulses ]
Table distance:
It defines the length of the first fold, or alignment of the front
edge of linen with other folds. If the first fold is longer than
the others (for example, the front edge of linen sticks out over
the other folds after folding) it is necessary to decrease the
value of this parameter. If the first fold is shorter than the oth-
ers (for example, the front edge of linen does not reach the
length of other folds after folding) it is necessary to increase
the value of this parameter.
4. Correction after measuring the length
[Input: pulses ]
Length correct.:
Due to different speeds of the feeding table, pressure roller,
and ironing rollers, linen length measuring may be inaccurate,
which causes an inaccurate finishing of the folding (the last
fold is not in the middle when folding with constant width of
the fold, or it has different length than others when folding
with a constant number of folds). It is possible to eliminate
this inaccuracy by adjusting the setting of this parameter for
the most frequently used kind of linen. Therefore, if for exam-
ple the last fold is too long, it is necessary to decrease the val-
ue of this parameter or if for example the last fold is too short-
er, it is necessary to increase the value of this parametr.
5. Speed factor of the folding table drive:
[Input: i factor ]
Motor 2:
It defines the ratio of the folding table belt's speed to the iron-
ing belt's speed. Higher value means higher speed of the fold-
ing table.
6. Type of heating:
[1:St/2:Gas/3:Elec]
Heating system:
This parameter defines the type of heating. Do not change this
parameter.
7. Reducing the back fold:
[Input: pulses ]
Rear fold cor.:
A Without correction
B With correction
Figure 8
Factory Setting
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
13
Part No. D1607ENR1
Содержание FCIFF2000/500 ELECTRIC
Страница 2: ......