Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
60. COOLING OR DRYING TIMER MOTOR
(Old Style Timers)
NOTE: Cooling and drying timers used prior to
January 1985 were supplied by Greenwald and
have serviceable timer motors. After January 1985,
Robert Shaw or Mallory timers are used, which do
not have serviceable timer motors. These later
timers must be replaced as complete assemblies if
the timer motor fails.
a. Remove control panel.
b. Disconnect motor leads.
c. Remove screws holding timer motor to
mounting bracket. Refer to Figure 4.
NOTE: Refer to wiring diagram when rewiring
timer motor.
d. Replacing Greenwald timer assembly with
Mallory timer assembly:
(1) Remove Greenwald timer assembly.
(2) Connect timer terminal wire 3 to terminal
board terminal B.
(3) Connect timer terminal 5 wire to terminal
board terminal C.
Figure 3
BRACKET
T341S
DRYING
LIGHT
LOCKING
TABS
COOLING
LIGHT
TIMER
KNOB
TIMER
RELAY
RESISTORS
MANUAL TIMER
MODELS