Alliance Laundry Systems D715I Скачать руководство пользователя страница 18

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation

510963

16

Manufactured (Mobile) Home 
Installation

The dryer can be installed in a manufactured (mobile) 
home by following these instructions:

1.

IMPORTANT: Gas dryers MUST be 
permanently attached to the floor at the time 
of installation. Order No. 526P3 Dryer 
Installation Kit for a manufactured (mobile) 
home installation. Follow the instructions 
supplied with the kit.

2. Electrical Connections (Electric Dryer Only) 

must be a 4-wire connection, refer to page 19.

3. Venting – Dryer MUST be exhausted to the 

outdoors.

The dryer can be exhausted to the outdoors 
through the back, left, right or bottom panel. Gas 
dryers cannot be exhausted out the left side 
because of the burner housing.

The dryer exhaust duct must be secured to the 
mobile home structure.

Exhaust ducts MUST NOT be connected with 
sheet metal screws or fasteners which extend into 
the duct.

Exhaust duct must not be connected to any other 
duct, vent or chimney.

Dryer exhaust duct MUST NOT terminate under 
the mobile home.

For proper operation, it is important that the dryer 
has an ample amount of outside make-up air. The 
free area of any opening for the introduction of 
outside air must be at least 25 in

2

 (163 cm

2

).

When exhausting the dryer to the outdoors, the 
dryer can be installed with “0” inch clearance at 
the sides and rear. Clearance of the duct from 
combustible construction must be a minimum of 
2 inches (5.08 cm).

Venting materials are not supplied with the dryer 
(obtain locally).

IMPORTANT: Installation must conform to 
the Manufactured Home Construction and 
Safety Standards, Title 24 CFR, Part 32-80 
or Standard CAN/CSA-Z240 MH.

To reduce the risk of fire and combustion 
gas accumulation, the dryer MUST BE 
EXHAUSTED TO THE OUTDOORS. Refer to 
Section on Dryer Exhaust Requirements.

W047

WARNING

To reduce the risk of fire, the exhaust duct 
and weather hood MUST be fabricated of a 
material that will not support combustion. 
Rigid or flexible metal pipe is recommended 
for a clothes dryer.

W048

WARNING

Содержание D715I

Страница 1: ...rs Electric and Gas Models D715I Part No 510963R5 June 2007 Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine Para bajar una copia de es...

Страница 2: ......

Страница 3: ...flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in yo...

Страница 4: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 2 510963 Notes...

Страница 5: ...Dryer Only Connect Gas Supply Pipe 10 Step 4 Electric Dryer Only Connect Electrical Plug 11 Step 5 Wipe Out Inside of Dryer 12 Step 6 Plug In the Dryer 13 Step 7 Check Installation 13 Heat Source Chec...

Страница 6: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 4 510963 Notes...

Страница 7: ...placement Parts If replacement parts are required contact the source where you purchased your dryer or contact Alliance Laundry Systems LLC Shepard Street P O Box 990 Ripon WI 54971 0990 Phone 920 748...

Страница 8: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 510963 6 Notes...

Страница 9: ...m 43 in 109 2 cm 4 0 in 10 2 cm 15 44 in 39 2 cm 26 9 in 68 3 cm ELECTRIC DRYERS 22 38 in 56 85 cm 40 25 in 102 24 cm 15 4 in 39 1 cm DRY2209N With leveling legs turned into base 1 3 8 in NPT Gas Conn...

Страница 10: ...unded receptacle NOTE For more detailed information refer to Section on Electrical Requirements If the supply cord is damaged it must be replaced by a special cord or assembly available from the manuf...

Страница 11: ...duct is as short as possible Be certain old ducts are cleaned before installing your new dryer Use 4 inch 102 mm diameter rigid or flexible metal duct The male end of each section of duct must point...

Страница 12: ...reads when removing the cap 3 Connect to gas supply pipe 4 Tighten all connections securely Turn on gas and check all pipe connections internal external for gas leaks with a non corrosive leak detecti...

Страница 13: ...lectrical Plug Connection NOTE Four wire cord is required for mobile homes or where codes do not permit grounding through neutral Figure 8 D275I 1 Typical Three Wire Receptable 2 Power Cord Three Wire...

Страница 14: ...n and a damp cloth to remove shipping dust from inside dryer drum Figure 10 D680I 1 L1 Terminal 2 Neutral Terminal 3 L2 Terminal 4 Black Wire 5 White Wire Neutral 6 Strain Relief Not supplied with dry...

Страница 15: ...al Requirements and connect the dryer to an electrical power source Figure 11 Figure 12 Step 7 Check Installation Refer to Installer Checklist on the back cover of this manual and make sure that dryer...

Страница 16: ...pt gas ignition After the dryer has operated for approximately five minutes observe burner flame through lower front panel Adjust the air shutter to obtain a soft uniform blue flame A lazy yellow tipp...

Страница 17: ...ull down removing door liner from door panel DRY1916N 4 Rotate door panel 180 degrees as shown D273P DRY1917N 5 Remove door strike from door liner and reinstallonopposite side DRY1917N DRY1918N B A 6...

Страница 18: ...ct Exhaust duct must not be connected to any other duct vent or chimney Dryer exhaust duct MUST NOT terminate under the mobile home For proper operation it is important that the dryer has an ample amo...

Страница 19: ...isted on nameplate such as 208 Volt If branch circuit to dryer is fifteen feet 4 50 m or less in length use U L Underwriters Laboratories listed No 10 AWG wire copper wire only or as required by local...

Страница 20: ...ck in Dryer NOTE The power cord pigtail is NOT supplied with the electric dryer Type of pigtail and gauge of wire must conform to local codes and instructions The method of wiring the dryer is optiona...

Страница 21: ...wer cord or wires where they enter the dryer cabinet 6 Check the continuity of the ground connection before plugging the cord into an outlet Use an acceptable indicating device connected to the center...

Страница 22: ...to the terminal block as follows a Red wire to L1 terminal b Black wire to L2 terminal c White wire to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the ground wire...

Страница 23: ...9I To reduce the risk of fire electric shock serious injury or death all wiring and grounding MUST conform with the latest edition of the National Electrical Code ANSI NFPA 70 or the Canadian Electric...

Страница 24: ...cian should correct the problem Do not operate other appliances on the same circuit when this appliance is operating D090I 1 L1 2 Ground 3 Neutral 4 Round Grounding Prong 5 Neutral Side 1 2 3 4 5 STAN...

Страница 25: ...at test pressures in excess of 1 2 psi 3 45 kPa Refer to Figure 13 NOTE When connecting to a gas line an equipment shut off valve must be installed within 6 feet 1 8 m of the dryer An 1 8 in NPT pipe...

Страница 26: ...Use only if allowed by local codes Use Design CSA Certified Connector 4 Black Iron Pipe Shorter than 20 ft 6 1 m Use 3 8 in 9 5 mm pipe Longer than 20 ft 6 1 m Use 1 2 in 12 7 mm pipe 2 1 8 in NPT Pip...

Страница 27: ...m clearances are shown below Figure 27 D823I 1 Closet Door 2 Centered Air Openings G 2 Openings minimum 3 Outer Wall of Enclosure NOTE For new installations locate top of wall vent 42 inches 106 7 cm...

Страница 28: ...gy efficient homes with low air infiltration rates should be equipped with an air exchanger that can accommodate on demand make up air needs in the home These devices can be obtained through your buil...

Страница 29: ...out the left side because of the burner housing Dryer is shipped from factory ready for rear exhaust no kits required Exhausting the dryer through sides or bottom can be accomplished by installing a D...

Страница 30: ...in two halves that can be separately attached to the dryer and wall outlet Once attached the dryer can be slid back into position and the two halves can be connected from the front Figure 30 Dryer Air...

Страница 31: ...the cabinet Use only a damp or sudsy cloth for cleaning the control panel Some spray prewash products may harm the finish on the control panel NOTE The wiring diagram is located inside the control pa...

Страница 32: ...ance Laundry Systems LLC Shepard Street P O Box 990 Ripon WI 54971 0990 Date Purchased Model Number Serial Number Dealer s Name Dealer s Address Phone Number Service Agency Service Agency Address Phon...

Страница 33: ......

Страница 34: ...Level the Dryer LEVEL D255I LEVEL NIVEL D256I D259I Connect Dryer Exhaust System DRY1915N CHECK DRY1915N Connect Gas Supply Pipe Check for Gas Leaks D258I CHECK GAS ONLY D699I CHECK ELECTRIC ONLY Con...

Отзывы: