No Visible Display on Control
NOTE: Make sure the unit is plugged into a live outlet.
(1)
Is there 120 Volts AC
at output board
"H1-4" to "H1-6"?
(2)
Is there 12 Volts DC
at the output board
"H2-4" to "H2-5"?
Yes
Check for power at
the wall outlet.
Check wiring from
plug.
No
(3)
Is there 12 Volts DC
on front end control
"H2-4" to "H2-5"?
Yes
Replace output board.
No
Replace front end
control.
Yes
Check harness for
damage Replace if
needed.
No
Troubleshooting Electronic Control
©