Vend Price
AtS
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL WARM (
∧
) or the DELICATES COLD
(
∨
) keypad until
Prog
appears in the display. Press the
START (enter) keypad.
AtS
will appear in the display.
3. Press the START (enter) keypad. All LEDs will be lit to show
which cycle/temperature price is being programmed.
4. Press the NORMAL WARM (
∧
) or the DELICATES COLD
(
∨
) keypad to increase or decrease the value of the fifth digit.
NOTE: The vend price can be set from 0 to 65,535.
The factory default setting is 200.
5. Press the START (enter) keypad to enter the fifth digit and
display remaining four digits. The active digit will flash one
second on and one second off.
NOTE: To go back to the current programmable op-
tion without changing the value, press the PERM
PRESS WARM (<) keypad.
6. Press the NORMAL WARM (
∧
) or the DELICATES COLD
(
∨
) keypad to increase or decrease the value of the active digit
and the START (enter) keypad to enter the value of the digit
and advance to the next digit.
7. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Coin 1 Value
dEn1
This option allows the owner to set a specific numerical value for
a coin entered. For example, in the United States the coin value
for one quarter would be measured in cents (25). Therefore, the
coin value entered for one quarter would be 00025.
If the Vend Price is set for “.75”, and the Coin Value is set for
“00025”, the vend price displayed will decrease by 0.25 for each
coin entered and 3 coins will need to be entered to satisfy the
vend price.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL WARM (
∧
) or the DELICATES COLD
(
∨
) keypad until
Prog
appears in the display. Press the
START (enter) keypad, and
AtS
will appear in the display.
3. Press the NORMAL WARM (
∧
) or the DELICATES COLD
(
∨
) keypad to scroll through the programmable options until
dEn1
appears in the display.
4. When
dEn1
appears in the display, press the START (enter)
keypad. There are five digits in the Coin 1 Value. The fifth
digit will appear in the display and will flash one second on,
one second off.
5. Press the NORMAL WARM (
∧
) or the DELICATES COLD
(
∨
) keypad to increase or decrease the value of the fifth digit.
NOTE: The coin value can be set from 1 to 65,535.
The factory default setting is 25.
6. Press the START (enter) keypad to enter the fifth digit and
display remaining four digits. The active digit will flash one
second on and one second off.
NOTE: To go back to the current programmable op-
tion without changing the value, press the PERM
PRESS WARM (<) keypad.
7. Press the NORMAL WARM (
∧
) or the DELICATES COLD
(
∨
) keypad to increase or decrease the value of the active digit
and the START (enter) keypad to enter the value of the digit
and advance to the next digit.
8. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Coin 2 Value
dEn2
This option allows the owner to set a specific numerical value for
a coin entered when using a dual coin drop. For example, the coin
value for a dollar coin would be measured in cents (1.00). There-
fore, the coin value entered for one dollar coin would be 00100.
If the Vend Price is set for “2.00”, and the Coin Value is set for
“00100”, the vend price displayed will decrease by 1.00 for each
dollar coin entered.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL WARM (
∧
) or the DELICATES COLD
(
∨
) keypad until
Prog
appears in the display. Press the
START (enter) keypad, and
AtS
will appear in the display.
3. Press the NORMAL WARM (
∧
) or the DELICATES COLD
(
∨
) keypad to scroll through the programmable options until
dEn2
appears in the display.
4. When
dEn2
appears in the display, press the START (enter)
keypad. There are five digits in the Coin 2 Value. The fifth
digit will appear in the display and will flash one second on,
one second off.
5. Press the NORMAL WARM (
∧
) or the DELICATES COLD
(
∨
) keypad to increase or decrease the value of the fifth digit.
NOTE: The coin value can be set from 1 to 65,535.
The factory default setting is 100.
6. Press the START (enter) keypad to enter the fifth digit and
display remaining four digits. The active digit will flash one
second on and one second off.
NOTE: To go back to the current programmable op-
tion without changing the value, press the PERM
PRESS WARM (<) keypad.
7. Press the NORMAL WARM (
∧
) or the DELICATES COLD
(
∨
) keypad to increase or decrease the value of the active digit
and the START (enter) keypad to enter the value of the digit
and advance to the next digit.
Programming Control
©