Troubleshooting
53. CD Models: No Start With Vend Satisfied and Start Button Pushed
120 Volt/60 Hertz/1 Phase Gas Nonreversing
NOTE: All voltage checks are referenced to neutral unless stated otherwise.
NOTE: If motor only runs with start switch pressed in, that means centrifugal switch in motor is bad.
Replace motor.
CD Models: No start with
vend satisfied and start
button pushed
Is there
voltage to
the N.C. terminal
of switch A?
TMB2180S
Correct wiring
between L1 on
TBI and
switch A.
No
Unit
operational.
Is there
voltage
to COM terminal
of switch A?
Check for proper
operation of
switch A.
Replace switch A
if necessary.
Is
there voltage
to COM terminal
of the door
switch?
Correct wiring
between door
switch and switch
A of the rotary coin
drop.
With the
door closed, is
there voltage to the
N.O. terminal of the
door switch?
Check door
switch for
proper
operation,
replace if
necessary.
Is there
voltage to
terminal 5 of
the motor?
Correct wiring
between
motor and
door switch.
Is there
voltage to the input
side of the start
switch?
Correct wiring
between start
switch and
door switch.
With the
start button pressed
in, is there voltage to the
output side of the start
button?
Replace start
switch.
Is there
voltage to
terminal 1 of
the motor?
Correct wiring
between
motor and
start switch.
Yes
No
Yes
No
Yes
No
No
No
Yes
No
Yes
No
Yes
Does the
motor run?
Replace the
motor.
Yes
Yes
No
Yes