Troubleshooting
51. CD Models: No Heat With Vend Satisfied and Unit Running
120 Volt/60 Hertz/1 Phase and 240 Volt/60 Hertz/1 Phase Gas Nonreversing Models
CD Models: No Heat
with vend satisfied
and unit running
Is there
voltage on red wire
of the motor?
TMB2178S-a
Replace
motor.
No
Is
there voltage
to the input of
the cabinet
high limit?
Correct wiring
between cabinet
high limit and
motor.
Is
there voltage
to the output of the
cabinet high
limit?
Check for proper
operation.
Replace if
necessary.
Is
there voltage
to the COM terminal
of the airflow
switch?
Correct wiring
between airflow
switch and cabinet
high limit.
Is
there voltage
to the N.O. terminal
of the airflow
switch?
Check for proper
operation and
airflow. Replace
switch if
necessary.
Is
there voltage
to the input side of
the stove high limit
thermostat?
Correct wiring
between stove
limit and airflow
switch.
Is
there voltage
to the output side of
the stove high limit
thermostat?
Check for proper
operation and
airflow. Replace
stove high limit if
necessary.
Is
there voltage
to the N.C. terminal
of switch B on the
coin drop?
Correct wiring
between switch B
and stove high
limit.
Yes
No
Yes
No
Yes
No
No
No
Yes
No
Yes
No
Yes
Continued on
next page
Yes
Is
there voltage
to the COM terminal
of switch B?
Check for proper
operation of coin
drop. Replace
switch B if
necessary.
Yes
No
Is
there voltage
to the input side
of the adjustable
thermostat?
Correct wiring
between
switch B and
thermostat.
Yes
No
Yes