Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
17. MOTOR RUNS BUT NO HEAT
IGNITER
SPARKING
NO
YES
IEI CONTROL
IN SAFETY
LOCKOUT
NO
RESISTANCE OF
HIGH VOLTAGE
LEAD GREATER
THAN 28,000 OHMS
OR LESS THAN
10,500 OHMS
NO
IGNITER GAP IS NOT
5/32 INCH (.397 CM)
OR CERAMIC
CRACKED
NO
OPEN AND CLOSE
DOOR
REPLACE
HIGH VOLTAGE
LEAD
REGAP OR
REPLACE
IGNITER
YES
YES
YES
GAS SHUT-OFF
VALVE TURNED ON
GREEN WIRE
FROM IEI
CONTROL
CONNECTED TO
GROUND
TERMINAL
REPLACE
IEI CONTROL
YES
120 VOLTS
PRESENT ON
BLACK WIRE FROM
IEI CONTROL
YES
CHECK GAS VALVE
COIL FOR OPEN
CIRCUIT
YES
NO
TURN ON
GAS SHUT-OFF
VALVE
NO
REPLACE
IEI CONTROL
YES
REPLACE
GAS VALVE
CONNECT GREEN
WIRE TO GROUND
TERMINAL
NO