6

Place the dryer in position, and adjust the legs until the 

dryer is level from side to side and front to back. The 

dryer must not rock.

Figure 3 

IMPORTANT: In mobile home installations, gas 

dryers MUST be permanently attached to the floor 

at the time of installation. Order No. 526P3 Dryer 

Installation Kit (available at extra cost) for a 

manufactured (mobile) home installation. Follow 

the instructions supplied with the kit.

Step 2: Connect Dryer Exhaust System

DO NOT use plastic, thin foil or type B ducting. 

Rigid metal duct is recommended.

Locate dryer so exhaust duct is as short as 

possible.

Be certain old ducts are cleaned before installing 

your new dryer.

Use 4 inch (102 mm) diameter rigid or flexible 

metal duct.

The male end of each section of duct must point 

away from the dryer.

Use as few elbows as possible.

Use of duct tape or pop-rivets on all seams and 

joints is recommended, if allowed by local codes. 

DO NOT use sheet metal screws or fasteners on 

exhaust pipe joints which extend into the duct 

and catch lint.

DRY2345N

1

Dryer Base

2

Level

3

Leveling Leg

1

2

3

To reduce the risk of fire and combustion 

gas accumulation the dryer MUST be 

exhausted to the outdoors.

W604

To reduce the risk of fire and the 

accumulation of combustion gases, DO 

NOT exhaust dryer air into a window well, 

gas vent, chimney or enclosed, unventilated 

area, such as an attic, wall, ceiling, crawl 

space under a building or concealed space 

of a building.

W045

WARNING

DRY688N

Figure 4 

This gas appliance contains or produces a 

chemical or chemicals which can cause 

death or serious illness and which are 

known to the State of California to cause 

cancer, birth defects, or other reproductive 

harm. To reduce the risk from substances in 

the fuel or from fuel combustion, make sure 

this appliance is installed, operated, and 

maintained according to the instructions in 

this manual.

W115

To reduce the risk of fire, DO NOT use 

plastic or thin foil ducting to exhaust the 

dryer.

W354

WARNING

DRY688N

DON’T

DO

Содержание ADG41F1

Страница 1: ...Installation Instructions for Front Control Dryers Dimensions 3 Inside...

Страница 2: ...lding or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installa...

Страница 3: ...Dimensions DRY2343N 23 5 in 59 7 cm 28 in 71 1 cm 0 4 in 1 1 cm 4 5 in 11 4 cm 41 2 in 104 6 cm 4 0 in 10 2 cm 26 875 in 68 3 cm 8 0 in 20 3 cm 15 4 in 39 1 cm 15 44 in 39 2 cm 37 44 in 95 1 cm...

Страница 4: ...d are Parts Included An accessories bag has been shipped inside your dryer It includes Installation Instructions User s Guide Dryer Rack Reply Card Warranty Bond Three screws electric dryers only Refe...

Страница 5: ...elevated 18 inches 46 cm above the floor No other fuel burning appliance should be installed in the same closet with the dryer The dryer must not be installed or stored in an area where it will be exp...

Страница 6: ...se death or serious illness and which are known to the State of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in the fuel or from fuel combusti...

Страница 7: ...ny opening for the introduction of outside air must be at least 25 in 2 163 cm2 In mobile home installations dryer exhaust duct must be secured to mobile home structure Dryer exhaust duct MUST NOT ter...

Страница 8: ...t pipe must have a weather hood with hinged dampers obtain locally NOTE Weather hood should be installed at least 12 inches 30 5 cm above the ground Larger clearances may be necessary for installation...

Страница 9: ...on nameplate located in the door recess Use a new flexible stainless steel connector Use pipe joint compound insoluble in L P Liquefied Petroleum Gas or Teflon tape on all pipe threads Purge air and s...

Страница 10: ...inch water column pressure For proper operation at altitudes above 3000 feet 915 m the L P gas valve spud orifice size must be reduced to ensure complete combustion Refer to Table 3 Grounding Informa...

Страница 11: ...yer should be of maximum rated voltage 208 or 240 Volt depending on heating element listed on the nameplate Do not connect dryer to 110 115 or 120 Volt circuit Heating elements are available for field...

Страница 12: ...Type of power cord and gauge of wire must conform to local codes and instructions The method of wiring the dryer is optional and subject to local code requirements NOTE Connect the dryer to the power...

Страница 13: ...to the terminal block Refer to Figure 9 Connecting Power Cord with Four Wire Plug NOTE Four wire cord is required for new branch circuit installations mobile homes or where codes do not permit ground...

Страница 14: ...in Step 5 Ground to neutral wire will be attached to the neutral terminal in Step 6 5 Attach power cord ground green wire to rear bulkhead using ground screw removed in Step 3 DRY2468N 1 Ground Screw...

Страница 15: ...ly reversible To reverse door proceed as follows 1 Remove four hinge attaching screws 5 Remove door strike from door liner and reinstall on opposite side 6 Insert liner under flange on bottom of door...

Страница 16: ...electrical supply and comes equipped with a 3 prong grounding plug Refer to serial plate for specific electrical requirements NOTE The wiring diagram is located behind the control panel inside the co...

Страница 17: ...cord having an equipment grounding conductor and a 3 prong grounding plug The three prong grounding plug on the power cord should be plugged directly into a polarized three slot effectively grounded r...

Страница 18: ...five minutes observe burner flame through lower front panel Adjust the air shutter to obtain a soft uniform blue flame A lazy yellow tipped flame indicates lack of air A harsh roaring very blue flame...

Страница 19: ......

Страница 20: ...nstalling the Dryer Refer to the manual for more detailed information Position and Level the Dryer 1 D256I CHECK D259I LEVEL D255I D255I 2 Connect Dryer Exhaust 6 Wipe Out Inside of Dryer CHECK DRY204...

Отзывы: