background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installer Checklist

Fast Track for Installing the Dryer

(Refer to the manual for more detailed information)

 

 

• Position and 

Level the Dryer.

1

D256I

CHECK

D259I

LEVEL

D255I

D255I

2

DRY688N

DRY688N

• Connect Dryer 

Exhaust

System.

CHECK

3

GAS ONLY

D258I

CHECK

• Connect Gas 

Supply Pipe.

• Check for 

Gas Leaks.

4

D699I

W315IE0A

ELECTRIC ONLY

• Connect 

Electrical Cord.

CHECK

• Reverse Door,

if Desired.

5

DRY2051N

CHECK

DRY2051N

6

• Wipe Out Inside 

of Dryer.

CHECK

DRY2049N

DRY2049N

7

D275I

D254I

D254I

CHECK

Electric

Gas

• Plug In the Dryer.

D275I

• Recheck Steps 1-7.

8

CHECK

9

CHECK

D702I

• Check 

Heat Source.

D702I

Содержание ADG41F1

Страница 1: ...Installation Instructions for Front Control Dryers Dimensions 3 Inside...

Страница 2: ...lding or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installa...

Страница 3: ...Dimensions DRY2343N 23 5 in 59 7 cm 28 in 71 1 cm 0 4 in 1 1 cm 4 5 in 11 4 cm 41 2 in 104 6 cm 4 0 in 10 2 cm 26 875 in 68 3 cm 8 0 in 20 3 cm 15 4 in 39 1 cm 15 44 in 39 2 cm 37 44 in 95 1 cm...

Страница 4: ...d are Parts Included An accessories bag has been shipped inside your dryer It includes Installation Instructions User s Guide Dryer Rack Reply Card Warranty Bond Three screws electric dryers only Refe...

Страница 5: ...elevated 18 inches 46 cm above the floor No other fuel burning appliance should be installed in the same closet with the dryer The dryer must not be installed or stored in an area where it will be exp...

Страница 6: ...se death or serious illness and which are known to the State of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in the fuel or from fuel combusti...

Страница 7: ...ny opening for the introduction of outside air must be at least 25 in 2 163 cm2 In mobile home installations dryer exhaust duct must be secured to mobile home structure Dryer exhaust duct MUST NOT ter...

Страница 8: ...t pipe must have a weather hood with hinged dampers obtain locally NOTE Weather hood should be installed at least 12 inches 30 5 cm above the ground Larger clearances may be necessary for installation...

Страница 9: ...on nameplate located in the door recess Use a new flexible stainless steel connector Use pipe joint compound insoluble in L P Liquefied Petroleum Gas or Teflon tape on all pipe threads Purge air and s...

Страница 10: ...inch water column pressure For proper operation at altitudes above 3000 feet 915 m the L P gas valve spud orifice size must be reduced to ensure complete combustion Refer to Table 3 Grounding Informa...

Страница 11: ...yer should be of maximum rated voltage 208 or 240 Volt depending on heating element listed on the nameplate Do not connect dryer to 110 115 or 120 Volt circuit Heating elements are available for field...

Страница 12: ...Type of power cord and gauge of wire must conform to local codes and instructions The method of wiring the dryer is optional and subject to local code requirements NOTE Connect the dryer to the power...

Страница 13: ...to the terminal block Refer to Figure 9 Connecting Power Cord with Four Wire Plug NOTE Four wire cord is required for new branch circuit installations mobile homes or where codes do not permit ground...

Страница 14: ...in Step 5 Ground to neutral wire will be attached to the neutral terminal in Step 6 5 Attach power cord ground green wire to rear bulkhead using ground screw removed in Step 3 DRY2468N 1 Ground Screw...

Страница 15: ...ly reversible To reverse door proceed as follows 1 Remove four hinge attaching screws 5 Remove door strike from door liner and reinstall on opposite side 6 Insert liner under flange on bottom of door...

Страница 16: ...electrical supply and comes equipped with a 3 prong grounding plug Refer to serial plate for specific electrical requirements NOTE The wiring diagram is located behind the control panel inside the co...

Страница 17: ...cord having an equipment grounding conductor and a 3 prong grounding plug The three prong grounding plug on the power cord should be plugged directly into a polarized three slot effectively grounded r...

Страница 18: ...five minutes observe burner flame through lower front panel Adjust the air shutter to obtain a soft uniform blue flame A lazy yellow tipped flame indicates lack of air A harsh roaring very blue flame...

Страница 19: ......

Страница 20: ...nstalling the Dryer Refer to the manual for more detailed information Position and Level the Dryer 1 D256I CHECK D259I LEVEL D255I D255I 2 Connect Dryer Exhaust 6 Wipe Out Inside of Dryer CHECK DRY204...

Отзывы: