© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
512100
10
4. Tighten all connections securely. Turn on gas and
check all pipe connections (internal & external)
for gas leaks with a non-corrosive leak detection
fluid.
NOTE: The dryer and its appliance main gas valve
must be disconnected from the gas supply piping
system during any pressure testing of that system
at test pressures in excess of 1/2 psi (3.45 kPa).
Refer to
Step 9 (Check Heat Source)
.
L.P. (Liquefied Petroleum) Gas
, 2500 Btu/ft
3
(93.1 MJ/m
3
) service must be supplied at 10 ± 1.5 inch
water column pressure.
For proper operation at altitudes above 3000 feet (915 m)
the L.P. gas valve spud orifice size must be reduced to
ensure complete combustion. Refer to
Table 3
.
NOTE: DO NOT connect the dryer to L.P. Gas
Service without converting the gas valve. Install
L.P. Gas Conversion Kit 649P3, available at extra
cost.
Step 4: (Electric Dryer Only) Connect
Electrical Plug
Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz,
3 or 4 wire electrical supply. Refer to serial plate for
specific electrical requirements.
IMPORTANT: Use only a new U.L. listed No. 10
(copper wire only) three or four conductor power
supply cord kit rated 240 Volts (minimum) 30
Amperes and labeled as suitable for use in a clothes
dryer.
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
Grounding Information
This appliance must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. The cord-kit must be
equipped with a cord having an equipment-grounding
conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
Do not modify the plug provided with the cord-kit - if
it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
L.P. Altitude Adjustments
Altitude
Orifice Size
Part No.
feet
m
No.
inches
mm
3000
915
55
0.0520
1.32
58755
8000
2440
56
0.0465
1.18
503786
Table 3
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local
regulations as might apply. It is the
customer’s responsibility to have the wiring
and fuses installed by a qualified electrician
to make sure adequate electrical power is
available to the dryer.
W521
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk of
electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the dryer is properly
grounded.
W038
WARNING
Содержание ADG41F1
Страница 1: ...Installation Instructions for Front Control Dryers Dimensions 3 Inside...
Страница 19: ......