background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

7

802714R4

Step 3: Connect Fill Hoses

Water Supply

Water supply faucets must fit standard 3/4 inch 

(19.1 mm) female garden hose couplings. DO NOT 

USE SLIP-ON OR CLAMP-ON CONNECTIONS.
Water supply faucets should be readily accessible to 

permit turning them off when washer is not being 

used.
Recommended cold water temperature is 60

to 

80

o

Fahrenheit (16

o

 to 27

o

 Celsius). Recommended 

maximum hot water temperature is 125

o

 Fahrenheit 

(51

o

 Celsius). Warm water is a mixture of hot and cold 

water. Warm water temperature is dependent upon 

water temperature and pressure of both the hot and 

cold water supply lines.

Water pressure must be a minimum of 20 to a 

maximum of 120 pounds per square inch (138 to 

827 kPa) static pressure measured at the faucet.

NOTE: Water pressure under 20 pounds per 

square inch (138 kPa) will cause an extended fill 

time in the washer and may not properly flush out 

the detergent dispenser.

Turn on the water faucets and flush the lines for 

approximately two minutes to remove any foreign 

material that could clog the screens in the water 

mixing valve.

NOTE: When installing in newly constructed or 

renovated buildings, it is very important to flush 

the lines since build-up may have occurred during 

construction.

Connecting Hoses

Remove the two plain rubber washers and two filter 

screens from the accessories bag. Install them into 

each end of the fill hoses as shown in 

Figure 5

. The 

screen must be facing outward.
Screw hose couplings with the filter screens onto the 

water faucets until they are finger-tight. Then, using a 

pliers, screw approximately 1/4 turn. Use the red 

color-coded hose for the hot water connection and the 

blue color-coded hose for the cold water connection.
Screw hose couplings from other end of hoses onto the 

water mixing valve until they are finger-tight. Then, 

using a pliers, screw approximately 1/4 turn. Refer to 

Figure 6

. Make sure the red color-coded hose from the 

hot water faucet goes to the water mixing valve 

marked “H” and the blue color-coded hose from the 

cold faucet goes to the valve marked “C”.

 

IMPORTANT: Do not cross thread or overtighten 

couplings. This will cause them to leak.

Turn water on and check for leaks. If leaks are found, 

turn off the water, unscrew hoses and reinstall them 

until there are no leaks. 

IMPORTANT: Turn off water supply whenever 

there will be an extended period of non-use.

Mixing Valve Flow Rates

Pressure

(psi)

HOT 

gallons per minute

(liters per minute)

COLD 

gallons per minute

(liters per minute)

20

1.6 (6)

2.5 (9.4)

40

2.2 (8.2)

3.4 (13)

60

2.6 (9.9)

3.8 (14.5)

100

2.5 (9.6)

4.2 (15.9)

120

2.6 (9.8)

4.2 (15.9)

Under certain conditions, hydrogen gas 

may be produced in a hot water system 

that has not been used for two weeks or 

more. HYDROGEN GAS IS EXPLOSIVE. If 

the hot water system has not been used 

for such a period and before using the 

washer, turn on all hot water faucets and 

let the water flow from each for several 

minutes. This will release any 

accumulated hydrogen gas. The gas is 

flammable. Do not smoke or use an open 

flame during this time.

W029

WARNING

To prevent personal injury, avoid contact 

with inlet water temperatures higher than 

125

°

 Fahrenheit (51

°

 Celsius) and hot 

surfaces.

W748

WARNING

Содержание 802714R4

Страница 1: ...w speedqueen com Dimensions 3 Before You Start 4 Installation 4 Installer Checklist Back Cover Date Purchased _____________________________ Model Number _____________________________ Serial Number _____________________________ Part No 802714R4 March 2013 Inside Installation Instructions for Stacked Washers and Dryers ...

Страница 2: ...alified installer service agency or the gas supplier W052 FOR YOUR SAFETY the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death W033 WARNING Installation of unit must be performed by a qualified installer Install clothes dryer according to manufacturer s instructions and local codes DO NOT install a clothes ...

Страница 3: ... 54 in 137 2 cm 13 1 in 33 3 cm ELECTRIC DRYERS 14 6 in 37 08 cm 37 44 in 95 1 cm 1 5 in 3 8 cm 63 in 160 cm 24 in 61 cm SWD896N With leveling legs turned into base NOTE Exhaust openings are 4 in 10 2 cm metal ducting 1 3 8 in NPT Gas Connection 23 5 in 59 7 cm 28 in 71 1 cm 8 0 in 20 3 cm 75 25 in 191 1 cm 2 3 in 6 cm 15 4 in 39 1 cm 26 875 in 68 3 cm 44 1 in 112 cm 29 6 in 75 1 cm 31 1 in 79 cm ...

Страница 4: ...rate it until the unit has had a chance to warm up NOTE Some moisture in the wash drum is normal Water is used during testing at the manufacturer Installation Step 1 Position Unit Near Installation Area Move unit as close to the desired area of installation as possible NOTE For best performance and to minimize vibration or movement install washer on a solid sturdy and level floor Some floors may n...

Страница 5: ...sition on a solid sturdy and level floor Installing the unit on any type of carpeting soft tile a platform or other weakly supported structures is not recommended NOTE Shaded areas indicate adjacent structure SWD795N SWD795N A B C D E E Dryer and Exhaust Duct Clearances Area Description Minimum Clearance A Left Dryer Side 0 in 0 cm B Right Dryer Side 1 in 2 54 cm C Dryer Top 6 in 15 24 cm D Dryer ...

Страница 6: ...t rock tighten locknuts securely against bottom of unit base If these locknuts are not tight unit will move out of position during operation Leveling legs can be adjusted from inside the unit with a 7 8 inch deep well socket All four legs must rest firmly on the floor so the weight of the unit is evenly distributed The unit must not rock and must be level from side to side and front to back NOTE D...

Страница 7: ...ings with the filter screens onto the water faucets until they are finger tight Then using a pliers screw approximately 1 4 turn Use the red color coded hose for the hot water connection and the blue color coded hose for the cold water connection Screw hose couplings from other end of hoses onto the water mixing valve until they are finger tight Then using a pliers screw approximately 1 4 turn Ref...

Страница 8: ...period of non use NOTE Longer fill hoses are available as optional equipment at extra cost if the hoses supplied with the washer are not long enough for the installation Order hoses as follows No 20617 Fill Hose 8 feet 2 44 m No 20618 Fill Hose 10 feet 3 05 m Risers Risers or air cushions may have to be installed if the pipes knock or pound when flow of water stops The risers are more efficient wh...

Страница 9: ...ace around standpipe and drain hose and tighten strap to hold hose to standpipe Refer to Figure 8 This will prevent the drain hose from dislodging from drain receptacle during use Wall Installation For installations of this type the drain hose MUST be secured to one of the fill hoses using the beaded strap from accessories bag Refer to Figure 9 NOTE End of drain hose must not be below 24 in 61 cm ...

Страница 10: ...ed at minimum 5 0 inch water column pressure to maximum 10 5 inch water column pressure For proper operation at altitudes above 3000 feet 915 m the natural gas valve spud orifice size must be reduced to ensure complete combustion Refer to Table 1 SWD600N 1 Drain Hose 2 Tie Down Strap tape if necessary Figure 10 SWD600N 1 2 To reduce the risk of gas leaks fire or explosion The dryer must be connect...

Страница 11: ...J m3 service must be supplied at 10 1 5 inch water column pressure For proper operation at altitudes above 3000 feet 915 m the L P gas valve spud orifice size must be reduced to ensure complete combustion Refer to Table 2 NOTE DO NOT connect the dryer to L P Gas Service without converting the gas valve Install L P Gas Conversion Kit 649P3 available at extra cost Natural Gas Altitude Adjustments Al...

Страница 12: ...g on heating element listed on the nameplate Do not connect dryer to 110 115 or 120 volt circuit Heating elements are available for field installation in dryers which are to be connected to electrical service of different voltage than that listed on nameplate such as 208 Volt NOTE Branch circuit wire size requirements to laundry room outlet are shown in Table 3 The power cord connection between wa...

Страница 13: ...es or Circuit Breaker 6 Neutral 3 Neutral Wire 7 Terminal Block in Dryer NOTE The power cord is NOT supplied with the electric dryer Type of power cord and gauge of wire must conform to local codes and instructions The method of wiring the dryer is optional and subject to local code requirements NOTE Connect the dryer to the power supply with the MAXIMUM RATED VOLTAGE listed on the nameplate 1 3 5...

Страница 14: ...cord into an outlet Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet 8 Reinstall access cover and screw Connecting Power Cord with Four Wire Plug NOTE Four wire cord is required for mobile homes or where codes do not permit grounding through neutral Figure 16 1 Disconnect power to dryer 2 Remove access cover from r...

Страница 15: ...en installing the white wire loop the free eyelet end of the ground to neutral wire removed in Step 3 and attach along with the white wire to the neutral center terminal on the terminal block 7 Tighten all screws firmly IMPORTANT Failure to tighten these screws firmly may result in wire failure at the terminal block 8 Secure the strain relief to the power cord or wires where they enter the dryer c...

Страница 16: ...rd to reach locations can be done by installing 521P3 Flexible Metal Vent Kit available as optional equipment at extra cost Sufficient make up air must be supplied to replace the air exhausted by the dryer The free area of any opening for outside air must be at least 40 in 2 260 cm2 Failure to exhaust dryer properly will void warranty NOTE Venting materials are not supplied with the dryer obtain l...

Страница 17: ...not in operation outer end of exhaust pipe must have a weather hood with hinged dampers obtain locally NOTE Weather hood should be installed at least 12 inches 30 5 cm above the ground Larger clearances may be necessary for installations where heavy snowfall can occur NOTE The maximum length of a 4 in 10 2 cm diameter flexible metal duct must not exceed 7 87 ft 2 4 m as required to meet UL2158 cla...

Страница 18: ...ed and MUST be reinstalled whenever the unit is moved more than four feet Do not lift or transport unit from front or without shipping materials installed Refer to the User s Guide for proper instructions on reinstalling the shipping materials IMPORTANT DO NOT tip washer more than 6 inches 152 4 mm in any direction after shipping brace has been removed Shock absorbers may separate and damage to wa...

Страница 19: ...ectrical requirements NOTE The wiring diagram is located behind the control panel inside the control cabinet When plugging in the dryer Do not overload circuits Do not use an adapter Do not use an extension cord Do not operate both a washer and gas dryer on the same circuit Use separately fused 15 amp circuits SWD834N Figure 27 SWD603N Figure 28 D275I D275I Connect to 30 Amp circuit To reduce the ...

Страница 20: ... 15 Amps Do not modify the plug provided with the dryer if it will not fit the outlet have a proper outlet installed by a qualified electrician NOTE Have a qualified electrician check the polarity of the wall receptacle If a voltage reading is measured other than that illustrated the qualified electrician should correct the problem Do not operate other appliances on the same circuit when this appl...

Страница 21: ... the power cord should be plugged directly into a polarized three slot effectively grounded receptacle rated 110 120 Volts AC alternating current 15 Amps Refer to Figure 31 to determine correct polarity of the wall receptacle DRY2022N 1 L1 2 Ground 3 Neutral Side 4 Round Grounding Prong 5 Neutral Figure 31 1 2 3 4 5 Standard 120 Volt 60 Hertz 3 Wire Effectively Grounded Circuit 0 V A C 120 12 V A ...

Страница 22: ...s at high speed verify that it is stable 5 If it is not after cycle is complete refer to Step 2 and readjust leveling legs Step 12 Check Heat Source Electric Dryers Close the loading door and start the dryer in a heat setting refer to the Dryer User s Guide supplied with the unit After the dryer has operated for three minutes the exhaust air or exhaust pipe should be warm Gas Dryers IMPORTANT This...

Страница 23: ...urn the air shutter to the left to get a luminous yellow tipped flame then turn it back slowly to the right to obtain a steady soft blue flame 3 After the air shutter is adjusted for proper flame tighten the air shutter lockscrew securely 4 Reinstall the lower front panel After the dryer has operated for approximately three minutes exhaust air or exhaust pipe should be warm For personal safety low...

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...Valve Connection Connect Drain Hose to Drain Receptacle 4 SWD598N SWD598N CHECK Connect Gas Supply Pipe Check for Gas Leaks 5 Gas Only CHECK D434I Connect Electrical Cords 6 D679IE0A CHECK D679IEOA Electric Only SWD449N Connect Dryer Exhaust System 7 CHECK SWD449N Remove the Shock Sleeves and Shipping Brace 8 CHECK Washer Only FLW2124N FLW2124N SWD834N Wipe Out Inside of Washer and Dryer 9 CHECK S...

Отзывы: