Operating Instructions

19

70400101 (EN)

System Tests

The following system tests are performed during 

normal operation. System tests are performed at a 

minimum of every 24 hours. 

Low Voltage Detection

If the voltage between terminals TH and GND on the 

control is below 18.75VAC +/- 0.75VAC for more than 

3 seconds the ignition control will turn off the gas 

valve and will not attempt to spark. The Diagnostic 

LED will display Error Code 5. The ignition control 

will not enter Lockout Mode if a low voltage condition 

is detected, but will enter Standby Mode and wait for 

the low voltage condition to be cleared.
If the voltage between terminals TH and GND on the 

control rises above 19.75VAC +/- 0.1VAC for at least 

3 seconds, the ignition control will then enter Start Up 

Mode.
Low Voltage Detection test is disabled during Run 

Mode.

Gas Valve

The ignition control verifies that the gas valve is 

connected. Failure of this test results in the ignition 

control entering Lockout Mode with the Diagnostic 

LED displaying Error Code 2.

Flame Probe Tests

Unexpected Presence of Flame

The Unexpected Presence of Flame test is performed 

when no flame is expected. Failure of this test results 

in the ignition control entering Lockout Mode with the 

Diagnostic LED displaying Error Code 3. 

Flame Monitoring

During the Flame Monitoring test, the flame is 

checked to ensure the gas is being burned when the gas 

valve is on. Failure of this test will result in the 

ignition control entering Lockout Mode with the 

Diagnostic LED displaying Error Code 3. 

Diagnostic LED (DGN LED)

 

/ Error Codes

The Diagnostic LED or DGN LED is located by the 

power connector on the ignition control. Refer to 

Figure 9

. The Diagnostic LED will indicate the status 

of the ignition control. Refer to 

Table 5

.

The Diagnostic LED will flash error codes one half 

second on and one half second off. Error codes are 

separated by a one second pause before the code is 

repeated.

LED Color

Description

Orange-Yellow

Initialization 

Green

Standby / Normal Operation

Red

Fault Indication Code

Table 5 

Error 

Code

DGN LED status

Fault Type

1

Red 

Ignition Control Internal Failure

2

2 Red Flashes

Gas Valve Not Connected

3

3 Red Flashes

Ignition/Flame Sense Failure

4

4 Red Flashes

Reset Switch is Shorted

5

Slow Red and Green Flashes

Low Voltage Detection

6

Fast Red and Orange Flashes

Ignition Control is in Reset Delay

TMB2176N

1

Diagnostic (DGN) LED

Figure 9 

1

Содержание 602004144

Страница 1: ...cked 30 Pound Capacity Stacked 45 Pound Capacity Starting Serial No 0602004144 Refer to Page 3 for Model Numbers Part No 70400101R9EN July 2011 Keep These Instructions for Future Reference If this mac...

Страница 2: ......

Страница 3: ...our building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier ca...

Страница 4: ...4 Serial Plate Location 4 Wiring Diagram 4 Safety Information 5 Explanation of Safety Messages 5 Important Safety Instructions 6 Operating Instructions 8 Emergency Stop Button on CE Models 8 Operatin...

Страница 5: ...DRST30G2 BTT30L DRST30G2 BTT30N DRST30G2 BUT30L DRST30G2 BUT30N IPD30STG2 ITT30L IPD30STG2 ITT30N CHD30STS2 CTT30S CHD30STS2 CUT30S DRST30S2 BTT30S DRST30S2 BUT30S IPD30STS2 ITT30S CHD30STE2 CTT30E CH...

Страница 6: ...distributor For technical assistance call 920 748 3121 Serial Plate Location When calling or writing for information about your product be sure to mention model and serial numbers Model and serial nu...

Страница 7: ...ns electrical wiring regulations and any other relevant statutory regulations Because of varied requirements applicable local codes should be thoroughly understood and all pre installation work arrang...

Страница 8: ...5 If not installed operated and maintained in accordance with the manufacturer s instructions or if there is damage to or mishandling of this product s components use of this product could expose you...

Страница 9: ...fabric care instructions supplied by the garment manufacturer 27 Never operate the tumble dryer with any guards and or panels removed 28 DO NOT operate the tumble dryer if it is smoking grinding has m...

Страница 10: ...E Overloading causes slow drying and wrinkling Close loading door Tumble dryer will not operate with the door open Step 3 Determine Control Type and Temperature Setting Refer to the various controls p...

Страница 11: ...heating system will shut off and the motor will stop To restart the cycle both doors must be closed and the Start pad must be pressed 3 When the cycle is complete open door and remove laundry NOTE Th...

Страница 12: ...s from 0 60 desired 3 Set the COOL DOWN TIME for the number of minutes from 0 15 desired 4 Press and release START button to start tumble dryer Display will show minutes remaining before end of cycle...

Страница 13: ...the heat time display If the door is not opened the tumble dryer completes the selected cool down time If the door is opened after reaching Lr temperature the cycle will be terminated NOTE If display...

Страница 14: ...eck airflow switch to ensure that it is properly aligned and securely mounted in the mounting bracket Make sure airflow switch can open and close freely Check installation and make sure there is adequ...

Страница 15: ...p to 18 hours or until door is opened Preliminary Control Information Power Up Mode When power is applied to the tumble dryer the control will enter Ready Mode unless a cycle was in process prior to a...

Страница 16: ...ector is changed the new setting is displayed by flashing the IN USE LED as follows High Normal 4 flashes Medium PP 3 flashes Low Delicate 2 flashes No Heat 1 flash NOTE To change dipswitch settings r...

Страница 17: ...dependent on the number of coins that are inserted in the coin slot IMPORTANT To stop the tumbler at any time during the cycle OPEN DOOR To restart the tumbler CLOSE door and press START button 5 When...

Страница 18: ...top the tumble dryer at any time during the cycle OPEN DOOR To restart the tumble dryer CLOSE door and press START button 3 When the cycle is complete open door and remove the laundry Table 4 TMB2353N...

Страница 19: ...will occur within 11 seconds of initial flame loss Termination of Flame Normal flame termination occurs when the thermostat has been satisfied meaning there is no immediate need for more heat The ther...

Страница 20: ...r ignition The ignition control will re enter the 18 seconds waiting period before the ignition control makes another attempt at ignition If the three attempts at ignition fail the ignition control wi...

Страница 21: ...The Unexpected Presence of Flame test is performed when no flame is expected Failure of this test results in the ignition control entering Lockout Mode with the Diagnostic LED displaying Error Code 3...

Страница 22: ...sure that it does so Excessive gaps between the lint screen and the lint screen panel allow lint to pass into the ductwork system and may restrict airflow e Carefully wipe any accumulated lint off the...

Страница 23: ...ervicing Close gas shut off valve to gas tumble dryer before servicing Close steam valve to steam tumble dryer before servicing Never start the tumble dryer with any guards panels removed Whenever gro...

Страница 24: ...ble 4 Check flow of combustion and ventilation air 5 Check belt tension and condition Replace worn or cracked belts Bi Annually 1 Check mounting hardware for any loose nuts bolts or screws 2 Check gas...

Страница 25: ...e area surrounding tumble dryers remove all combustible materials including lint before operating the machine Check cylinder for foreign objects to avoid damage to clothing and equipment Clean lint fr...

Страница 26: ...am valve to steam tumble dryer before servicing Never start the tumble dryer with any guards panels removed Whenever ground wires are removed during servicing these ground wires must be reconnected to...

Страница 27: ...hese ground wires must be reconnected to ensure that the tumble dryer is properly grounded W002R1 WARNING Check mounting hardware for any loose nuts bolts or screws Check gas connections for leakage C...

Страница 28: ...butor For technical assistance call 920 748 3121 Won t Start Won t Heat Clothes Not Dry Possible Reason Corrective Actions Insert correct coin s or valid card if applicable Close the loading door tigh...

Отзывы: