RULES TO COMPLY WHILE USING AND WARRANTY CONDITIONS

10.

Either ALLFETT Mekanik ve Elektronik Sistemler SAN. TÝC. LTD. ÞTÝ or ALLFETT

Pazarlama ve Dýþ Ticaret LTD. ÞTÝ. are not responsible for damages on machines or

vehicles coming from reasons above.

9.

Damages occur while repairing the pump by unauthorized staff 

ARE NOT COVERED

UNDER  WARRANTY  SCOPE.

Except  the  conditions

 

mentioned

 

in

  “PUMP

MAINTENANCE INSTRUCTIONS” 

consult the technical service or leave the

maintenance to technical service.

8.

If the pump is working out of grease it will try to send air instead of grease and will

not provide any grease. Damages on pump and on the system coming from that

reason 

ARE NOT COVERED UNDER WARRANTY SCOPE.

7.

Grease to be used in the system must certainly be clean and any foreign material

must not enter while changing bucket. Damages coming from the small particules

inside  the  system 

ARE  NOT  COVERED  UNDER  WARRANTY  SCOPE.

6.

First check the grease to be in specifications of the pump. Use NLGI 0 for cold

weather, increase the NLGI class up to 2 for hot weathers. Grease should be Lithium

based and EP additive.

5.

Leaving an uncovered cable during electric connections might cause fatal damages

on voltage regulator. Cables must be installed properly and risk of electric shock

must take into consideration. Damages coming from low and high voltage, wrong

electric installation or using a different voltage from products specifications 

ARE

NOT COVERED UNDER WARRANTY SCOPE.

4.

Pumps have an electric driven motor and must connected to an appropriate electric

source and electrical connections must be done properly.

3.

Washing of the pump under pressured water is object to damages. Damages occur

from  this  reason 

ARE  NOT  COVERED  UNDER  WARRANTY  SCOPE

.

2.

Pumps are produced to lubrication purpose and are not convenient to work continious

more than 10 minutes. Working continuously under maximum pressure will harm the

system. Damages occur from this reason 

ARE NOT COVERED UNDER WARRANTY

SCOPE

.

1.

Damages occur while additional  transports after delivering the goods from ALLFETT

to  the  customer 

ARE  NOT  COVERED  UNDER  WARRANTY  SCOPE.

Содержание ALL-5 Mobile AC

Страница 1: ...ion Systems Equipment INTRODUCTION USER MANUAL Pleace read before using the product ELECTRICAL GREASE PUMP ALL 5 MOBILE AC YEARS WARRANTY THE PHYSICAL LIFE DETERMINED BY MINISTRY OF INDUSTRYAND TRADE OF TURKEY IS 10 YEARS ...

Страница 2: ... grease buckets can be used as reservoir Pump has one outlet and if more points are needed progressive distributors can divide one outlet s displacement dosages needed GENERAL SPECIFICATIONS Working pressure Motor type 200 bar 220 380 V AC 0 09 Kw Protection class Grease type Displacement Working temperature Reservoir capacity IP 55 NLGI 0 1 2 210 cm minute 25 C 80 C 16 20 Liters Max pressure 400 ...

Страница 3: ...FUSES GREASE OUTLET COUPLING 380 V AC ELECTRICAL CONNECTION Figure 2 11 12 13 14 15 16 17 18 19 ELECTRICAL CONNECTIONS GRAVITY GREASE TAKE IN SECTION GEARBOX 220 380 V AC MOTOR TOP COVER BRACKET PRESSURE SWITCH TOP COVER FOLLOWER PLATE 1 6 5 4 3 2 7 9 10 18 17 11 12 15 16 14 13 19 8 BLUE Cable NEUTRAL Connection YELLOW GREEN Cable GROUND Connection GREY Cable 380 V AC BLACK Cable 380 V AC BROWN Ca...

Страница 4: ...he pump should be plunged in horizontal position to the bucket Then get the pump body to vertical position and settle the pump by pushing forward and backward inside of the bucket There must be no air under the follower plate Pump is ready to lubricate 1 2 3 4 Top cover bracket 16 position for 16 liters grease can Top cover bracket 16 position for 20 liters grease can ...

Страница 5: ...ications of the pump Use NLGI 0 for cold weather increase the NLGI class up to 2 for hot weathers Grease should be Lithium based and EP additive 5 Leaving an uncovered cable during electric connections might cause fatal damages on voltage regulator Cables must be installed properly and risk of electric shock must take into consideration Damages coming from low and high voltage wrong electric insta...

Страница 6: ...rical connections and the cables 1c 1 If Pump is not running Please check the fuses Schema 2 right side on the electronic control card box 1b Using higher viscosity grease may couse low flowrate Please use NLGI 0 1 2 class grease 2d Pump could be taken air inside Open the top cover and push weight and follower plate down If this problem continue start up the pump until running out the air inside t...

Страница 7: ...nd Competition in accordance with the law numbered 4077 PRODUCER COMPANY FAX TELEPHONE CENTRAL ADRESS NAME 90 212 501 33 37 90 212 501 32 01 PBX AUTHORISED PERSON ÝMZASI KAÞESÝ PRODUCT TYPE Electrical grease pump BRAND ALLFETT MODEL SERIAL NUMBER DELIVERY DATE PLACE WARRANTY 2 Years REPAIR TIME 30 days ALL 5 MOBILE AC SALER COMPANY NAME CENTRAL ADRESS TELEPHONE BILL DATE NR FAX WARRANTY ...

Страница 8: ...ue of the parts replaced or any our charges The product will be replaced free of charge If the product permanently disfunctions due to repeating the same defect more than four times within the warranty period If the maximum period for repairing is exceeded If it is determined that the defect cannot be repaired by report written by the service or in the absence of service centers by the seller agen...