BY-PASS TYPE PUMP DESCRIPTION

ALL-5 Pumps by-pass system is a security relief system that protects pump and lines from over

pressure. Working pressure of the pump is adjusted with by-pass system. ALL-5 pump’s maximum pressure
limits are described below with piston diameters. If necessary, by-pass limit pressure can be adjusted to
different value. Please follow the steps below if needed.

Increase pressure

By-pass adjustment screw,
- turned CW (clockwise) to increase pressure

Decrease pressure

By-pass adjustment screw,
- turned CCW (counter clockwise) to decrease pressure

Adjusted pressure value can be controlled
by manometer on pump outlet.

Manometer

2.

1.

Maximum pressure (Ø12 piston)

 180 bar.

(Ø16 piston)

 180 bar.

(Ø20 piston)

 150 bar.

Содержание 10 24 16 E1

Страница 1: ...ALL 5 DC MOBILE type ELECTRICAL GREASE PUMP VERSION 2 50 INTRODUCTION AND USER MANUAL ...

Страница 2: ...ill be increased INTRODUCTION ABOUT MANUFACTURER With over 25 years experience of manufacturing Centralized Lubrication Systems ALLFETT is able to provide a wide professional approach to select the correct Centralized Lubrication System for industry and heavy machinery A highly accurate manufacturing process is involved in producing Centralized Lubrication Systems in order that systems meet the ve...

Страница 3: ... LUBRICANT INFORMATION STANDARD TYPE PUMP DESCRIPTION BY PASS TYPE PUMP DESCRIPTION ELECTRICAL CONNECTIONS BUCKET BARREL CHANGE RULES TO COMPLY WHILE USING AND WARRANTY CONDITIONS PUMP MAINTENANCE ORDER INFORMATION WARRANTY WARRANTY CONDITIONS PAGE 1 PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 6 PAGE 7 PAGE 8 PAGE 9 PAGE 10 PAGE 11 PAGE 12 PAGE 13 PAGE 14 PAGE 15 PAGE 17 ...

Страница 4: ...vide different requirements ALL 5 DC standard type pumps are controlled with pressure switch ALL 5 DC pumps can also work with by pass system PRODUCT DESCRIPTION GENERAL SPECIFICATIONS Working temperature 25 C 80 C Grease type NLGI 00 10 C 0 C NLGI 0 0 C 10 C NLGI 1 10 C 30 C Max pressure 24 V DC Motor type Motor protection class IP 54 Ø12 Ø16 piston 180 bar Ø20 piston 150 bar Pump outlet 1 outlet...

Страница 5: ...age represents the ALL 5 DC pumps which is used with grease buckets 16 and 20 liters bucket type pumps has 2 different height values There is no diversity between standard and by pass type pumps 426mm 416mm 975mm ALL 5 type pumps can be produced for different bucket volumes ...

Страница 6: ...nal specifications described seperately Elektrik kutusu Aç Kapa Þalteri Sigorta Kova kapaðý civatalarý Sýyýrýcý piston Pompa emiþ bölümü Z mafsal Kova kapak sacý baðlantý civatalarý Grease gun Kova kapaðý braketi DC motor Pressure switch By Pass system Opsiyonel Standard grease buckets must be purchased separatelly ...

Страница 7: ...C models has pressure relief system to control working pressure of the pump If lubrication point is blocked or back pressure is higher than working pressure by pass system opens the port inside reservoir to over pressure goes back inside Pump will continue to operate untill on off swich is turned off Displacement volume of the pump element can be connected to single lubrication point However displ...

Страница 8: ...een 10 C and 0 C for NLGI 1 grease recomended working temperature is between 0 C and 10 C for NLGI 2 grease recomended working temperature is between 10 C and 30 C Only LITHIUM based and EP additive liquid greases must be used with in system It is important that the grease will be used must resistant to high pressure Make sure the liquid grease you are using is EP additive ALL 5 pumps are designed...

Страница 9: ...elow if needed STEP 1 Remove the female socket part Use small screwdriver to loose its screw STEP 2 There is a hole center of male socket part 2mm allen will be used to adjust pressure Turn allen to set recomended limit pressure CW clockwise to increase pressure CCW counter clockwise to decrease pressure 2mm allen ALLFETT Pressure switch is NO normally open contact type Manometer Maximum pressure ...

Страница 10: ...low with piston diameters If necessary by pass limit pressure can be adjusted to different value Please follow the steps below if needed Increase pressure By pass adjustment screw turned CW clockwise to increase pressure Decrease pressure By pass adjustment screw turned CCW counter clockwise to decrease pressure Adjusted pressure value can be controlled by manometer on pump outlet Manometer 2 1 Ma...

Страница 11: ...ctrical motor Correct electrical energy should be connected Cover Electrical connection coupling Electrical cables 3 Electrical cables are marked with and signs 24 V DC electrical energy should be connected as it Electrical cable coupling Any maintenance on ALL 1 pumps under electrical voltage could lead to personal injury Disconnect all electrical power before any maintenance Unouthorized modific...

Страница 12: ...n while moving pump forward and backward slowly This movement avoids the pump take air Tighten the cover screws again Pump is now ready to operate 1 2 3 4 5 ALL 5 pumps doesn t have reservoir 16 or 20 liters standard grease buckets or barrels are used as reservoir To avoid contamination of lubricant and trouble free usage grease bucket or barrel must be changed with new one when its empty Follow t...

Страница 13: ...mage and to ensure that they are firmly in place 5 Pumps have an electric driven motor Electrical lines must be connected properly by qualified and instructed personel 4 3 Washing of the pump with pressured water causes damage Any damage occur from this reason DISQUALIFIES THE WARANTY 2 Pumps are produced to lubrication purpose only and are not convenient to work more than 5 minutes continuously W...

Страница 14: ...age of the lubrication point If ALLFETT electronic control card is connected the system Electronic control card may be in waiting period Wait until working time starts If necessary control card pass to working period by pressing ADDITIONAL CYCLE button a b c d e Grease inside bucket or barrel is empty Chance the grease bucket or barrel according to items in page 16 Pump may take air due to work wi...

Страница 15: ...Pressure switch 24 V DC Ø20 10 24 20 E1 10 24 20 E2 10 24 20 E3 ALL 5 Barrel type By pass system 24 V DC Ø12 ALL 5 Barrel type By pass system 24 V DC Ø16 ALL 5 Barrel type By pass system 24 V DC Ø20 11 24 20 B1 11 24 20 B2 11 24 20 B3 ALL 5 Bucket type Pressure switch 24 V DC Ø12 ALL 5 Bucket type Pressure switch 24 V DC Ø16 ALL 5 Bucket type Pressure switch 24 V DC Ø20 10 24 16 E1 10 24 16 E2 10 ...

Страница 16: ...Y PRODUCER COMPANY FAX TELEPHONE CENTRAL ADRESS NAME ALLFETT Mekanik ve Elektronik Sistemler San ve Tic Ltd Þti 0212 501 33 37 0212 501 32 01 PBX Yeni Eyup Bulvari Topcular Cad Set Ustu No 1 Demirkapý Rami Ýstanbul AUTHORISED PERSON SIGNATURE STAMP PRODUCT TYPE Electrical grease pump BRAND ALLFETT MODEL SERIAL NUMBER DELIVERY DATE PLACE WARRANTY 2 years REPAIR TIME 30 days ALL 5 Standard ALL 5 Wit...

Страница 17: ... risk for environmental and human health during use TRANSPORT AND STORAGE There are no restrictions on transportation by land air and sea In general products should be stored in a dry and dust free environment The storage temperatures are between 10 C and 40 C All products are packed with paper based support matarial to reduce damage Upon receiving the package please check the items for possible d...

Страница 18: ...d expenses of any sort including labor the value of the parts replaced or any our charges The product will be replaced free of charge If the product permanently disfunctions due to repeating the same defect more than four times within the warranty period If the maximum period for repairing is exceeded If it is determined that the defect cannot be repaired by report written by the service or in the...

Страница 19: ...PAGE 18 www allfett net NOTES ...

Страница 20: ......

Отзывы: