background image

Publication 22C-PC001D-EN-P - January 2017

Product Information 

PowerFlex 400 Adjustable Frequency AC 
Drive

Catalog Number 22C, Series B

 

Additional Resources

These documents contain additional information concerning the installation, programming, and application 
of the AC drive.

Mounting Considerations

Mount the drive upright on a flat, vertical and level surface.

Protect the cooling fan by avoiding dust or metallic particles.

Do not expose to a corrosive atmosphere.

Protect from moisture and direct sunlight.

Minimum Mounting Clearances

Frame C Mounting Clearances

Frames D, E and F Mounting Clearances

Frames G and H Mounting Clearances

Ambient Operating Temperatures

Drive Dimensions

PowerFlex 400 Frames

PowerFlex 400 Frames C...H

Dimensions are in mm and (in.). Weights are in kg and (lb).

Specifications, Fuses and Circuit Breakers 

ATTENTION: 

• Before installing, configuring, operating or maintaining this product,

read this document and the documents listed in the Additional
Resources section for installing, configuring, or operating
equipment. Users should familiarize themselves with installation and
wiring instructions in addition to requirements of all applicable
codes, laws, and standards.

• Installation, adjustments, putting into service, use, assembly, disassembly,

and maintenance shall be carried out by suitably trained personnel in
accordance with applicable code of practice.

• If this equipment is used in a manner not specified by the manufacturer, the

protection provided by the equipment may be impaired.

• Solid state equipment has operational characteristics differing from those of

electromechanical equipment. Safety Guidelines for the Application,
Installation and Maintenance of Solid State Controls, publication SGI-1.1,
available from your local Rockwell Automation sales office or online at

http://www.rockwellautomation.com/literature

describes some important

differences between solid state equipment and hard-wired
electromechanical devices.

ATTENTION: 

Do not install, configure, operate or maintain this product until you have read 

the product documentation and the documents in the Additional Resources section for 
installing, configuring, operating or maintaining equipment. To get the product 
documentation go to 

http://www.rockwellautomation.com/literature

 or contact your local 

sales office or Rockwell Automation representative.

ATTENTION: 

Ne pas installer, configurer, exploiter ou maintenir ce produit tant que vous 

n’avez pas lu sa documentation et les documents de la rubrique Documents connexes pour 
l’installation, la configuration, l’exploitation et la maintenance de l’équipement. Pour obtenir 
de la documentation, rendez-vous sur le site 

http://www.rockwellautomation.com/literature

 

ou contactez votre agence commerciale Rockwell Automation locale ou son représentant.

ACHTUNG: 

Für die Installation, Konfiguration, den Betrieb und die Wartung dieses Produkt 

lesen Sie sich bitte zunächst die Produktdokumentation sowie die Dokumente im Abschnitt 
"Weitere Informationen" durch. Die entsprechende Produktdokumentation finden Sie unter 

http://www.rockwellautomation.com/literature

 oder kontaktieren Sie Ihr lokales 

Vertriebsbüro bzw. einen Rockwell Automation-Mitarbeiter.

ATENCIÓN: 

No instale, configure, opere ni mantenga este producto hasta que haya leído la 

documentación del producto y los documentos en la sección Recursos adicionales para la 
instalación, configuración, operación o mantenimiento de equipo. Para conseguir la 
documentación, diríjase a 

http://www.rockwellautomation.com/literature

 o póngase en 

contacto con su oficina regional de ventas o representante de Rockwell Automation.

ATENÇÃO: 

Não instale, configure, opere ou mantenha este produto até que você leia a 

documentação do produto e os documentos na seção Recursos adicionais para a instalação, 
configuração, operação ou manutenção do equipamento. Para conseguir a documentação, 
visite 

http://www.rockwellautomation.com/literature

 ou entre em contato con seu escritório 

de vendas regional ou representante da Rockwell Automation.

ATTENZIONE: 

Non installare, configurare, attivare o riparare questo prodotto senza avere 

prima letto la relativa documentazione nonchè i documenti indicati nella sezione Ulteriori 
Risore riguardanti l'installazione, la configurazione, l'attivazione o la riparazione 
dell'apparecchiatura. Per la documentazione sul prodotto visitare il sito 

http://www.rockwellautomation.com/literature

 o contattare l'ufficio vendite o il 

rappresentate Rockwell Automation di zona.

ВНИМАНИЕ: 

Не устанавливайте, не конфигурируйте, не запускайте в эксплуатацию и не 

поддерживайте работу продукта до прочтения технической документации по продукту 
и документации в разделе Дополнительные материалы для инсталлирования, 
конфигурирования, запуска в эксплуатацию и поддержки работы продукта. Чтобы 
ознакомиться с документацией по продукту, перейдите по ссылке 

http://www.rockwellautomation.com/literature

 или свяжитесь с локальным офисом 

продаж или представителем Rockwell Automation.

UWAGA: 

Nie instaluj i nie uruchamiaj tego urządzenia dopóki nie zapoznasz się z instrukcją 

użytkownika produktu. Aby uzyskać dokumentację produktu przejdź do strony internetowej 

http://www.rockwellautomation.com/literature

 lub skontaktuj się z lokalnym biurem 

sprzedaży lub przedstawicielstwem firmy Rockwell Automation.

UPOZORŇENÍ: 

Neprovádějte instalaci, konfiguraci, provoz ani údržbu, pokud jste dosud 

nepřečetli dokumentaci k produktu a dokumenty obsažené v sekci Doplňující informace pro 
instalaci, konfiguraci, provoz a údržbu. Tuto dokumentaci můžete získat na 

http://www.rockwellautomation.com/literature

 nebo od obchodního zástupce společnosti 

Rockwell Automation.

English

This instruction sheet is available in multiple languages at 

http://www.rockwellautomation.com/literature

. Select publication language and type 

“22C-QS001“ in the search field.

Deutsch

Diese Anleitung steht in mehreren Sprachen unter 

http://www.rockwellautomation.com/literature

 zur Verfügung. Wählen Sie Ihre Sprache aus, 

und geben Sie „22C-QS001“ in das Suchfeld ein.

Français

Ces instructions sont disponibles dans différentes langues à l’adresse suivante: 

http://www.rockwellautomation.com/literature

. Sélectionner la langue puis taper 

« 22C-QS001 » dans le champ de recherche.

Italiano

La presente scheda d’istruzione è disponibile in varie lingue sul sito 

http://www.rockwellautomation.com/literature

. Selezionare la lingua desiderata e digitare 

“22C-QS001“ nel campo di ricerca.

Español

Puede encontrar esta hoja de instrucciones en varios idiomas en 

http://www.rockwellautomation.com/literature

. Selecione el idioma de publicación y 

escriba “22C-QS001“ en el campo de búsqueda.

Português Esta folha de instruções está disponível em várias línguas em 

http://www.rockwellautomation.com/literature

. Seleccione a língua de publicação e entre 

com “22C-QS001“ no espaço de busca.

ᵈᗧ㧦

ᵈᗧ㧦

⵾ຠߩ⾗ᢱ߅ࠃ߮ㅊട⾗ᢱߦ⸥タߩⵝ⟎ߩขઃߌޔ᭴ᚑޔᠲ૞ޔ

߹ߚߪ଻቞ߦ㑐ߔࠆ⾗ᢱࠍ߅⺒ߺߦߥࠆ߹ߢߪޔߎߩ⵾ຠߩขઃߌޔ
᭴ᚑޔᠲ૞ޔ߹ߚߪ଻቞ࠍⴕߥࠊߥ޿ߢߊߛߐ޿ޕ⵾ຠߩ⾗ᢱࠍ
౉ᚻߔࠆߦߪ

 

ޔ9GDࠨࠗ࠻㧦

http://www.rockwellautomation.com/literature

 

ߦ

ࠕࠢ࠮ࠬߔࠆ߆ޔ߹ߚߪࡠ࠶ࠢ࠙ࠚ࡞࡮ࠝ࡯࠻ࡔ࡯࡚ࠪࡦߩ༡ᬺ߹ߚߪ
⽼ᄁઍℂᐫ߹ߢߏㅪ⛊ߊߛߐ޿ޕ

주의사항

주의사항

 : : 

제품

 

매뉴얼

 

혹은설치

 , 

구성

 , 

가동

 , 

유지와

 

관련된

 

추가

 

지침서를

 

완전히

 

숙지하기

 

전까지

 

본 제품을

 

설치

 

혹은

 

가동하

 

 

마십시오

 . 

 

제품과

 

관련된 매뉴얼

 

혹은

 

문서를

 

원하시면

 

사이트

 

http://www.rockwellautomation.com/literature

 

 

방문

 

해주시거나

 

해당

 

지역의

 

로크웰

 

오토메이션대리점으

 

 

문의하십시오

 .   

注意

注意:若未阅读产品文档以及

“ 

其它资源

” 

小节中提及的有关安装、配置、

运行或维护设备的相关文档,请勿安装、配置、运行或维护本产品。请访问

 

http://www.rockwellautomation.com/literature

 

或联系您当地的销售办事处或

罗克韦尔自动化代表,以获取产品文档。

注意:

注意:

 

在您完整閱讀本產品相關文件及其他關於安裝、

 

配置、

 

操作或

維護設備等資料之前、

 

請勿安裝、

 

配置、

 

操作或維護此產品。您可到下列

網站下載所有產品相關文件

 

http://www.rockwellautomation.com/literature 

或聯繫洛克威爾自動化當地辦公室。

한국의

http://www.rockwellautomation.com/literature

 

 

 

 

 

 

 

 

 "22C-QS001"

 

.

中文

(

简体

)

从以下网页可以获得本说明书的多种语言的版本

http://www.rockwellautomation.com/literature

 

请选择出版物的语言

并在搜索栏输入“22C-QS001”

 

印。

ᣣᧄ

ᧄ⺑᣿ᦠࠪ࡯࠻ߩᄙ⸒⺆ ߪ9GDࠨࠗ࠻

http://www.rockwellautomation.com/literature

ߦߡ౉ᚻߢ߈ߔޕ಴ ⸒⺆ࠍㆬᛯߒޔᬌ⚝ࡈࠖ࡯࡞࠼ߦޟ%35ޠ
ߣ࠲ࠗࡊߒߡߊߛߐ޿ޕ

Русский

Данное руководство на других языках можно найти по адресу 

http://www.rockwellautomation.com/literature

. Выберите язык и введите в окно поиска 

«22C-QS001».

Český

Tato stránka s pokyny je k dispozici ve více jazykových verzích na adrese 

http://www.rockwellautomation.com/literature

. Zvolte jazyk publikace a do vstupního pole 

pro vyhledávání zadejte „22C-QS001“.

Polski

Niniejsza instrukcja dostępna jest w wielu językach na stronie 

http://www.rockwellautomation.com/literature

. Wybrać język publikacji, w polu 

wyszukiwania wpisać “22C-QS001”.

PowerFlex 400 User Manual 

22C-UM001

: Detailed information on the parameters and specifications of the 

PowerFlex 400 adjustable frequency drive.

AC Drive Installation Considerations 

DRIVES-IN003

: Provides additional information needed to properly 

install PowerFlex AC drives.

Wiring and Grounding Guidelines for Pulse Width Modulated (PWM) AC Drives, publication 

DRIVES-IN001

Provides basic information needed to properly wire and ground PWM AC drives.

Industrial Automation Wiring and Grounding Guidelines 

1770-4.1

: Provides general guidelines for 

installing a Rockwell Automation industrial system.

Frame Screw Size Screw Torque

C

M5 (#10...24) 2.45...2.94 Nm (22...26 lb-in.)

D

M8 (5/16 in.) 6.0...7.4 Nm (53.2...65.0 lb-in.)

E

M8 (5/16 in.) 8.8...10.8 Nm (78.0...95.3 lb-in.)

F

M10 (3/8 in.) 19.6...23.5 Nm (173.6...208.3 lb-in.)

G

M12 (1/2 in.) 33.5...41.0 Nm (296.5...362.9 lb-in.)

H

M12 (1/2 in.) 33.5...41.0 Nm (296.5...362.9 lb-in.)

Frame Temperature Range Enclosure Rating

Minimum Mounting
Clearances

C

-10...45 °C (14...113 °F) IP20/UL Open Type

Use Mounting Option A

-10...45 °C (14...113 °F) IP30/NEMA 1/UL Type 1

(1)

(1)

Frame C drives require installation of the PowerFlex 400 IP30/NEMA 1/UL Type 1 option kit to achieve this
rating.

Use Mounting Option B

-10...50 °C (14...122 °F) IP20/UL Open Type

Use Mounting Option B

D, E, F, 
G, H

-10...45 °C (14...113 °F) IP30/NEMA 1/UL Type 1

See Frames D, E and F Mounting Clearances 
and Frames G and H Mounting Clearances

中文
(繁體)

以下網頁提供本說明書的多國語言版本:

http://www.rockwellautomation.com/literature 

。請選擇出版語言,並於搜尋欄鍵入

Ā&46ā

 

即可。

120 mm

(4.7 in.)

120 mm

(4.7 in.)

25 mm

(1.0 in.)

120 mm

(4.7 in.)

120 mm

(4.7 in.)

120 mm

(4.7 in.)

120 mm

(4.7 in.)

120 mm

(4.7 in.)

120 mm

(4.7 in.)

Mounting Option A

No clearance required
between drives.

Mounting Option B

Closest object that
may restrict air flow
through the drive heat
sink and chassis

150 mm

(6.0 in.)

150 mm

(6.0 in.)

50 mm

(2.0 in.)

50 mm

(2.0 in.)

250 mm

(9.8 in.)

150 mm

(6.0 in.)

50 mm

(2.0 in.)

50 mm

(2.0 in.)

Frame D and E

Frame F

300 mm

(11.8 in.)

300 mm

(11.8 in.)

300 mm

(11.8 in.)

300 mm

(11.8 in.)

Output Power

Frame Size

kW

HP

200...240V AC Input 400...480V AC Input

2.2...7.5

3...10

C

C

11...15

15...20

D

C

18.5...22 25...30

D

D

30...37

40...50

E

E

45...75

60...100

E

90...110

125...150 –

F

132...160 200...250 –

G

200...250 300...350 –

H

Drive Ratings

Catalog No.

Output Rating

Input Rating

Branch Circuit Protection

Power
Dissi-
pation

kW
(HP)

Amps Voltage

Range

kVA Amps Fuses

(1)

(1)

Recommended Fuse Type: UL Class J, CC, T or Type BS88; 600V (550V) or equivalent.

140M Motor
Protectors

(2) (3) (4)

(2)

Refer to the MCS Miniature Modular Control System Selection Guide, publication

MCS-SG001

to determine

the frame and breaking capacity required for your application.

(3)

The AIC ratings of the Bulletin 140M Motor Protector Circuit Breakers may vary. See

Bulletin 140M Motor

Protection Circuit Breakers Application Ratings

.

(4)

Manual Self-Protected (Type E) Combination Motor Controller, UL listed for 208 Wye or Delta, 240 Wye or
Delta, 480Y/277 or 600Y/347. Not UL listed for use on 480V or 600V Delta/Delta, corner ground, or
high-resistance ground systems.

Min.
Enclosure
Volume

(5)

(in.

3

)

(5)

When using a Manual Self-Protected (Type E) Combination Motor Controller, the drive must be installed in a
ventilated or non-ventilated enclosure with the minimum volume specified in this column. Application specific
thermal considerations may require a larger enclosure.

IP20
Open
Watts

50 °C

200...240V AC – 3-Phase Input, 0...230V 3-Phase Output

22C-B012N103 2.2 (3.0)

12

180...265 6.5

15.5

20

140M-F8E-C16 5098

146

22C-B017N103 3.7 (5.0)

17.5

180...265 8.8

21

30

140M-F8E-C25 5098

207

22C-B024N103 5.5 (7.5)

24

180...265 10.9

26.1

35

140M-F8E-C32 5098

266

22C-B033N103 7.5 (10)

33

180...265 14.4

34.6

45

140M-F8E-C45 5098

359

22C-B049A103

11 (15)

49

180...265 21.3

51

70

488

22C-B065A103

15 (20)

65

180...265 28.3

68

90

650

22C-B075A103

18.5 (25)

75

180...265 32.5

78

100

734

22C-B090A103

22 (30)

81

180...265 38.3

92

125

778

22C-B120A103

30 (40)

120

180...265 51.6

124

175

1055

22C-B145A103

37 (50)

130

180...265 62.4

150

200

1200

380...480V AC – 3-Phase Input, 0...460V 3-Phase Output

22C-D6P0N103 2.2 (3.0)

6

340...528 6.3

7.5

10

140M-D8E-C10 5098

105

22C-D010N103 4.0 (5.0)

10.5

340...528 10.9

13

20

140M-D8E-C16 5098

171

22C-D012N103 5.5 (7.5)

12

340...528 11.9

14.2

20

140M-D8E-C16 5098

200

22C-D017N103 7.5 (10)

17

340...528 15.3

18.4

25

140M-D8E-C20 5098

267

22C-D022N103 11 (15)

22

340...528 19.2

23

30

140M-F8E-C32 5098

329

22C-D030N103 15 (20)

27

340...528 25.8

31

40

140M-F8E-C32 5098

435

22C-D038A103 18.5 (25)

38

340...528 33.3

40

50

140M-F8E-C45 9086

606

22C-D045A103 22 (30)

45.5

340...528 39.1

47

60

738

22C-D060A103 30 (40)

54

340...528 53.3

64

80

664

22C-D072A103 37 (50)

72

340...528 60.7

73

100

1019

22C-D088A103 45 (60)

88

340...528 74.9

90

125

1245

22C-D105A103 55 (75)

105

340...528 89

107

150

1487

22C-D142A103 75 (100)

128

340...528 124.8 150

200

2043

22C-D170A103 90 (125)

170

340...528 142

170

250

2617

22C-D208A103 110 (150) 208

340...528 167

200

250

3601

22C-D260A103 132 (200) 260

340...528 196

235

300

3711

22C-D310A103 160 (250) 290

340...528 242

290

400

4208

22C-D370A103 200 (300) 370

340...528 304

365

500

4916

22C-D460A103 250 (350) 410

340...528 387

465

600

6167

Agency Certifications

Listed to UL508C and CAN/CSA-22.2

Certified to AS/NZS, 1997 Group 1, 
Class A

Marked for all applicable European Directives

EMC Directive: 2014/30/EU: EN 61800-3
LV Directive: 2014/35/EU: EN 61800-5-1

The drive is also designed to meet the appropriate portions of the following specifications:

NFPA 70 – US National Electrical Code
NEMA ICS 3.1 – Safety standards for Construction and Guide for Selection, Installation and Operation
of Adjustable Speed Drive Systems.
IEC 146 – International Electrical Code.

Control Inputs

Digital inputs, programmable/semi-programmable

Analog inputs, isolated -10...10V or 4...20 mA/
non-isolated 0...10V or 4...20 mA

SRC (Source) mode:

18...24V = ON
0...6V = OFF

SNK (Sink) mode:

0...6V = ON
18...24V = OFF

Resolution: 10-bit
4...20 mA analog: 250 

 input impedance

0...10V DC analog: 100 k

 input impedance

External pot: 1...10 k

, 2 W min

Control Outputs

Relay output, programmable 
form C
Resistive rating: 3.0 A @ 30V DC, 
125V AC and 240V AC
Inductive rating: 0.5 A @ 30V DC, 
125V AC and 240V AC

Opto outputs, programmable

30V DC, 50 mA non-inductive

Analog output, non-isolated

Resolution: 10-bit
0...10V DC analog: 1 k

 min

4...20 mA analog: 525 

 max

Protective Features

Motor Protection:

I

2

t overload protection – 110% for 60 s (Provides Class 10 protection)

Overcurrent: 180% hardware limit, 220% instantaneous fault

A

E

B

D

105.8

(4.17)

24.5

(0.96)

138.2

(5.44)

C

244

(9.61)

300

(11.81)

325

(12.8)

Frame

A

B

C

D

E

Weight

(1)

(1)

Weights include HIM and Standard I/O.

C

130.0 (5.1)

260.0 (10.2)

180.0 (7.1)

116.0 (4.57)

246.0 (9.7)

4.33 (9.5)

D

250.0 (9.84)

436.2 (17.17)

206.1 (8.11)

226.0 (8.90)

383.4 (15.09)

14.0 (30.9)

E

370.0 (14.57)

605.5 (23.84)

259.2 (10.21)

335.0 (13.19)

567.4 (22.34)

51.2 (112.9)

F

425.0 (16.73)

850.0 (33.46)

264.0 (10.39)

381.0 (15.00)

647.5 (25.49)

88.0 (194.0)

G

425.0 (16.73)

892.0 (35.12)

264.0 (10.39)

381.0 (15.00)

819.5 (32.26)

106 (233.7)

H

529.2 (20.83)

1363.8 (53.69)

358.6 (14.12)

480.0 (18.90)

1119.0 (44.06)

177 (390.2)

IP20/66 (NEMA Type 1/4X/12)

Flange Mount for Frame C

IP20/NEMA/UL Type Open

UL

®

C

US

All manuals and user guides at all-guides.com