88
Rockwell Automation Publication 2711P-UM006A-EN-P - November 2010
Chapter 5
Windows CE Operating System
Monitors
The Monitors tab of the PanelView Hardware Monitor applet provides
continuous temperature, voltage, and load information for the terminal.
Battery Voltage
The Monitors tab provides a visual status and voltage reading of the battery for
the real-time clock. The actual battery voltage is updated at powerup and then
every hour.
Temperatures
The Monitors tab provides a visual status and current temperature of the terminal
display and logic module CPU. The temperature is updated every 10 seconds.
Table 37 - Battery Conditions
Condition
Logic Module Battery
Depleted
Less than 2.0V indicates a dead battery or no power.
Low
2.0…2.74V
Normal
2.75V or higher
Table 38 - Temperature Conditions
Condition
Logic Module CPU
Display
Low
–
10 °C (50 °F) or lower
Normal
25…94 °C (77…201 °F)
11…59 °C (52…138 °F)
High
95 °C (203 °F) and higher
60 °C (140 °F) and higher
Содержание PanelView Plus 6 1000
Страница 10: ...10 Rockwell Automation Publication 2711P UM006A EN P November 2010 Preface Notes ...
Страница 32: ...32 Rockwell Automation Publication 2711P UM006A EN P November 2010 Chapter 2 Install Terminal Notes ...
Страница 100: ...100 Rockwell Automation Publication 2711P UM006A EN P November 2010 Chapter 5 Windows CE Operating System Notes ...
Страница 154: ...154 Rockwell Automation Publication 2711P UM006A EN P November 2010 Chapter 9 Troubleshoot the System Notes ...
Страница 158: ...158 Rockwell Automation Publication 2711P UM006A EN P November 2010 Appendix A Specifications Notes ...
Страница 167: ......