Connect the Kinetix 5700 Drive System
Wiring Guidelines
Use these guidelines as a reference when wiring the power connectors on your
Kinetix 5700 drive modules.
Follow these steps when wiring the connectors for your Kinetix 5700 drive
modules.
1.
Prepare the wires for attachment to each connector plug by removing
insulation equal to the recommended strip length.
Some cables come prepared with wires appropriately stripped.
2.
Route the cable/wires to your Kinetix 5700 drive module connector.
3.
Insert wires into connector plugs.
Refer to the connector pinout tables in
or the interconnect
.
4.
Tighten the connector screws.
5.
Gently pull on each wire to make sure it does not come out of its
terminal; reinsert and tighten any loose wires.
6.
Insert the connector plug into the drive module connector.
Wiring the Power Connectors
This section provides examples and guidelines to assist you in making
connections to the input power connectors.
Refer to
for an interconnect diagram.
Wire the 24V Control Power Input Connector
The 24V power (CP) connector requires 24V DC input for the control
circuitry. The connector plug ships with the drive module and shared-bus
connector kits are purchased separately.
IMPORTANT
For connector locations of the Kinetix 5700 drive modules, refer to
on
.
When removing insulation from wires and tightening screws to secure the
wires, refer to the table on
for strip lengths and torque values.
IMPORTANT
To improve system performance, run wires and cables in the wireways as
established in
.
IMPORTANT
Use caution not to nick, cut, or otherwise damage strands as you
remove the insulation.