Rockwell Automation Publication 2198-IN014A-EN-P - August 2018
Kinetix 5700 Regenerative Bus Supply
Catalog Number Explanation
This publication applies to the following Kinetix 5700 regenerative bus supplies.
Regenerative Bus Supply Catalog Numbers
Before You Begin
Prepare all equipment and hardware that is used to lift the regenerative bus supply before you
unpack and lift the module out of the shipping container.
Parts List
The Kinetix 5700 regenerative bus supplies include the following accessory items:
• DC-bus end caps
• Wiring plug connector set for mains input power (IPD), 24V control input power (CP),
digital inputs (IOD), shunt power (RC), and contactor enable (CED)
• Wiring plug connector for shunt power (RC) connections installed on the module
• These installation instructions, publication 2198-IN014
Regenerative Bus Supply
Cat. No.
Module
Width
mm
Input Voltage
(1)
(1)
Applies when DC-bus voltage regulation is enabled. If DC-bus voltage regulation is not enabled, then the input voltage range is 324….528V AC.
For more information on these two modes of operation, see the Kinetix 5700 Servo Drives User Manual, publication
Continuous
Output Power
kW
Continuous
Output Current
A
DC
rms
2198-RP088
165
324…506V AC rms,
three-phase
24
35
2198-RP200
275
67
100
2198-RP263
440
119
176
2198-RP312
140
207
TIP
Replacement connector sets (catalog numbers 2198-KITCON-RP088, 2198-KITCON-RP200, and
2198-KITCON-RP312) are also available. See the Kinetix Servo Drives Specifications Technical Data,
publication
, for more information.