Allen-Bradley Kinetix 5700 Series Скачать руководство пользователя страница 18

18

Rockwell Automation Publication 2198-IN014A-EN-P - August 2018

Kinetix 5700 Regenerative Bus Supply

Specifications

Attribute

2198-RP088

2198-RP200

2198-RP263

2198-RP312

Surrounding air temperature

Operating
Storage

0…50 °C (32…122 °F)
-40…70 °C (-40…158 °F)

Weight, kg (lb) approx

13.6 (30)

38.6 (85)

61.2 (135)

61.2 (135)

Short-circuit current rating

200,000 A rms symmetrical

Branch-circuit short-circuit 
protection

Integral solid-state short circuit protection does not provide branch circuit protection. Branch 
circuit protection must be provided in accordance with the National Electric Code (NEC) and any 
additional local codes.

Leakage 
current

• Kinetix 5700 drives produce leakage current in the protective-earthing conductor that exceeds 3.5 mA AC and/

or 10 mA DC. The minimum size of the protective-earthing (grounding) conductor used in the application must 
comply with local safety regulations for high-protective-earthing conductor current equipment.

• Kinetix 5700 drives produce DC current in the protective-earthing conductor and can reduce the ability of a 

residual current device (RCD) or residual current monitor (RCM) of type A or AC to provide protection for the 
drive module and other equipment in the installation.

Содержание Kinetix 5700 Series

Страница 1: ...s User Manual publication 2198 UM002 for detailed information on wiring applying power troubleshooting and integration with ControlLogix 5580 controllers with EtherNet IP communication modules or Comp...

Страница 2: ...Wiring plug connector for shunt power RC connections installed on the module These installation instructions publication 2198 IN014 Regenerative Bus Supply Cat No Module Width mm Input Voltage 1 1 Ap...

Страница 3: ...ight specifications These lifting instructions apply to catalog numbers 2198 RP200 2198 RP263 and 2198 RP312 ReadtheLiftingPrecautions Read these precautions before attempting to lift the regenerative...

Страница 4: ...secure the appropriate hardware in the designated lift points as identified in the illustrations ATTENTION To guard against equipment damage verify that the hardware is securely connected to the corre...

Страница 5: ...rt the module to the installation location IMPORTANT When approaching the full upright vertical position the weight can shift and cause the module to swing unexpectedly Control the movement of the mod...

Страница 6: ...s User Manual publication 2198 UM002 to determine the ground jumper setting ATTENTION Risk of equipment damage exists The input power ground configuration must be accurately determined When the ground...

Страница 7: ...nd right of the module is required when mounted adjacent to noise sensitive equipment or clean wire ways The recommended minimum cabinet depth is 300 mm 11 81 in Ground Configuration 1 1 Refer to the...

Страница 8: ...generative bus supply can be mounted on the far right far left or anywhere in between However the far left position is preferred to accommodate the 24V shared bus IMPORTANT Mounttheregenerativebussupp...

Страница 9: ...Hole 345 13 58 Lower Mounting Hole 420 16 54 Lower Mounting Hole 465 18 31 Lower Mounting Hole 27 5 55 0 40 0 55 0 110 55 0 110 110 165 110 110 0 00 IMPORTANT Hole spacing is measured in millimeters a...

Страница 10: ...etix 5700 drive modules Regenerative Bus Supply Cat No A mm in B mm in C mm in D mm in E 1 mm in 1 Maximum distance between lift points 2198 RP088 165 6 50 300 11 8 358 14 1 252 9 92 198 7 80 2198 RP2...

Страница 11: ...ve Bus Supply Features and Indicators on page 12 7 4 12 5 9 8 11 6 6 13 17 16 10 14 3 15 18 19 DC DC DC 24V 24V L3 L2 L1 MOD NET 2 1 1 I O 6 5 10 OK OK EN EN 5700 DC 2 1 15 20 19 20 2198 RP088 and 219...

Страница 12: ...twork status indicator 18 24V control input power CP connector 9 LCD display 19 AC Input power IPD connector 1 1 Connector plug orientation applies to 2198 RP088 and 2198 RP200 modules 2198 RP200 conn...

Страница 13: ...n 2198 UM002 for wiring examples Control Input Power CP Connector Pinout RC Pin Description Signal 2 Active shunt connections DC 1 DC CED Pin Description Signal OK Relay driven contact that provides a...

Страница 14: ...plied 24V supply COM 3 24V current sinking fast input 2 IN2 4 I O common for customer supplied 24V supply COM 5 Chassis ground SHLD 6 24V current sinking fast input 3 IN3 7 I O common for customer sup...

Страница 15: ...7 0 0 28 0 22 0 25 1 9 2 2 DC Bus power Bus bar DC DC N A 1 1 SharedDC bus powerconnectionsarealwaysmadefromdrivetodriveoverthebus barconnectionsystem Theseterminalsdonot receivediscrete wires N A 1 N...

Страница 16: ...dle high current inrush as well as fuses Make sure that the selected components are properly coordinated and meet acceptable codes which includes requirements for branch circuit protection Evaluation...

Страница 17: ...rives User Manual publication 2198 UM002 Bussmann Fuses Cat No Mersen Fuses Cat No Miniature CB Cat No Motor Protection CB Self Protected CMC Cat No Molded Case CB Cat No 2198 RP088 324 506V AC rms LP...

Страница 18: ...t protection must be provided in accordance with the National Electric Code NEC and any additional local codes Leakage current Kinetix 5700 drives produce leakage current in the protective earthing co...

Страница 19: ...IP networking and component servo drive families Kinetix Motion Accessories Specifications Technical Data publication KNX TD004 Provides product specifications for Bulletin 2090 motor and interface ca...