14
Rockwell Automation Publication 2198-IN014A-EN-P - August 2018
Kinetix 5700 Regenerative Bus Supply
Digital Inputs (IOD) Connector Pinout
Ethernet Communication PORT1 and PORT2 Pinout
Wiring Requirements
Wire must be copper with 75
°
C (167
°
F) minimum rating. Phasing of mains AC power is
arbitrary and earth ground connection is required for safe and proper operation.
IOD Pin
Description
Signal
1
24V current sinking fast input #1
IN1
2
I/O common for customer-supplied 24V supply
COM
3
24V current sinking fast input #2
IN2
4
I/O common for customer-supplied 24V supply
COM
5
Chassis ground
SHLD
6
24V current sinking fast input #3
IN3
7
I/O common for customer-supplied 24V supply
COM
8
24V current sinking fast input #4
IN4
9
I/O common for customer-supplied 24V supply
COM
10
Chassis ground
SHLD
Port Pin
Description
Signal
1
Transmit port (+) data terminal
+ TX
2
Transmit port (-) data terminal
- TX
3
Receive port (+) data terminal
+ RX
4
–
–
5
–
–
6
Receive port (-) data terminal
- RX
7
–
–
8
–
–
IMPORTANT
The National Electrical Code and local electrical codes take precedence over the values and
methods provided.
1
2
3
4
5
6
7
8
9
10
1
8