Chapter 4
CIP Axis Attributes
196
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
See also
Command Generator Configuration Attributes
These are the current control configuration attributes associated with a Motion
Control Axis.
Current Vector Limit
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Optional - CF
Set/SSV
REAL
100
FD
0
10
3
% Motor Rated
Current Vector Limit value applied to current vector limiter to provide a
configurable limit to the magnitude of the current vector.
Torque Loop Bandwidth
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Optional - C
Set/SSV
REAL
0
FD
0
Loop Bandwidth Units
The Torque Loop Bandwidth attribute determines the Iq Proportional Gain value
that multiplies the Iq Current Error signal before applying it to the Iq decoupling
summing junction as part of the torque producing current loop. In cases where the
torque producing current loop is controlled by something other than the
traditional PI regulator, the Torque Loop Bandwidth is used by the drive to
provide single parametric control of the current loop bandwidth. If the Flux Loop
Bandwidth is not supported, the drive will use the Torque Loop Bandwidth for
tuning both the torque producing and flux producing current loops.
Torque Integral Time Constant
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Optional - C
Set/SSV
REAL
0
0
Seconds
The Torque Integral Time Constant value determines the response time of the
torque producing current loop integrator. When used for Pole-Zero cancelation,
this value is set to the electrical time constant of the motor. A value of 0 for the
Torque Integral Time Constant disables the integrator.
Current Control Configuration