58
Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Chapter 3
Connector Data and Feature Descriptions
Motor Brake Circuit
The brake option is a spring-set holding brake that releases when voltage is
applied to the brake coil in the motor. The customer-supplied 24V power supply
drives the brake output through a relay.
Wire the Brake Control Circuit
One digital output can be used for motor brake control. In this example,
OUTPUT6 is used. Wire the brake control circuit according to the appropriate
Kinetix 5100 Drive/Rotary Motor Wiring Examples
beginning on
. External customer-supplied 24V power supply is
required.
Figure 36 - Brake Control Circuit Example
(1) Customer-supplied diode or MOV suppression device.
An example brake circuit contains the following components:
• Digital output 40 mA (max) continuous current.
• Relay 700-HK36Z24 with DIN mount 700-HN121 or equivalent
• Suppression device examples include 1N4004 diode,
Bulletin 199-MSMV1 MOV, or equivalent
See
for coil current ratings and brake
response times.
46
40
OUTPUT6–
BR+
BR–
2198-E
xxxx
-ERS
Kinetix 5100 Servo Drive
I/O Connector with
2198-TBIO Expansion Block
Relay
Motor Brake
Connections
Customer Supplied
+24V DC
Servo Motor
(1)
(1)
TIP
Choose relay rated for 40 mA continuous current or less.
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......