60
Rockwell Automation Publication 2097-UM002D-EN-P - April 2017
Chapter 4
Connect the Kinetix 350 Drive System
Power Wiring Requirements
The wire must be made of copper with 75 °C (167 °F) minimum rating.
Phasing of main AC power is arbitrary and an earth ground connection is
required for safe and proper operation. See
on
for interconnect diagrams.
Table 24 - Kinetix 350 Drive Power Wiring Requirements
IMPORTANT
The National Electrical Code and local electrical codes take precedence over
the values and methods provided.
Cat. No.
Description
Terminals
Recommended Wire Size
mm² (AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
Pins
Signals
2097-V31PR0-LM
2097-V32PR0-LM
2097-V32PR2-LM
2097-V33PR1-LM
2097-V33PR3-LM
2097-V34PR3-LM
2097-V34PR5-LM
2097-V34PR6-LM
Mains input power
(IPD connector)
L3
L2
L1
PE
(3)
L2/N
L1
N
PE
(4)
L2
L1
PE
(5)
Motor power cable depends
on motor/drive combination.
2.5 (14)
7 (0.28)
0.5 (4.5)
2097-V32PR4-LM
2097-V33PR5-LM
4.0 (12)
7 (0.28)
0.5 (4.5)
2097-V31PR2-LM
2097-V33PR6-LM
6.0 (10)
7 (0.28)
0.56…0.79
(5.0…7.0)
2097-V31PR0-LM
2097-V31PR2-LM
2097-V32PR0-LM
2097-V32PR2-LM
2097-V32PR4-LM
2097-V33PR1-LM
2097-V33PR3-LM
2097-V33PR5-LM
2097-V34PR3-LM
2097-V34PR5-LM
2097-V34PR6-LM
Motor power
(MP connector)
PE
W
V
U
2.5 (14)
7 (0.28)
0.5 (4.5)
2097-V33PR6-LM
4.0 (12)
7 (0.28)
0.5 (4.5)
2097-V31PR0-LM
2097-V31PR2-LM
2097-V32PR0-LM
2097-V32PR2-LM
2097-V32PR4-LM
2097-V33PR1-LM
2097-V33PR3-LM
2097-V33PR5-LM
2097-V34PR3-LM
2097-V34PR5-LM
2097-V34PR6-LM
Shunt/DC Bus
(1)
(BC connector)
+
+
SH
-
-
2.5 (14)
7 (0.28)
0.5 (4.5)
2097-V33PR6-LM
4.0 (12)
7 (0.28)
0.5 (4.5)
2097-V3
x
PR
x
-LM
Control back-up power
(BP connector)
+24V DC
-24V DC
1.5 (16)
6 (0.25)
0.5 (4.5)
2097-V3
x
PR
x
-LM
Safe torque-off
(STO connector)
STO-1
(2)
STO-2
STO-3
STO-4
STO-5
STO-6
+24V DC Control
Control COM
Safety Status
Safety Input 1
Safety COM
Safety Input 2
(1) Use for only shunt resistor connection.
(2) Use for bypassing only the STO circuit.
(3) Applies to 2097-V33PR
x
-LM, and 2097-V34PR
x
-LM drive modules.
(4) Applies to 2097-V31PR
x
-LM drive modules.
(5) Applies to 2097-V32PR
x
-LM drive modules.
Содержание Kinetix 350
Страница 4: ...4 Rockwell Automation Publication 2097 UM002D EN P April2017 Summary of Changes Notes ...
Страница 50: ...50 Rockwell Automation Publication 2097 UM002D EN P April2017 Chapter 3 Kinetix 350 Drive Connector Data Notes ...
Страница 154: ...154 Rockwell Automation Publication 2097 UM002D EN P April2017 Appendix C Leakage Current Specifications Notes ...
Страница 159: ...Rockwell Automation Publication 2097 UM002D EN P April2017 159 Index Notes ...
Страница 160: ...160 Rockwell Automation Publication 2097 UM002D EN P April2017 Index ...
Страница 161: ......