Limits Categories
The Limits categories provide access to the configuration of the modifiable
velocity and position limit parameters.
Velocity Limits
Table 45 - Velocity Limits Category
ID
Parameter Name
Description
Value/Notes
58
Zero Speed
Value in user units/s below which the drive will set the Zero Speed Digital Output (if
configured) and the VelocityStandstillStatus bit in the EtherNet/IP Input Assembly.
Range: 0…100 rpm
59
Speed Window
Value in user units/s for the target velocity for which the drive will set the In-Speed
Window Digital Output (if configured) and the VelocityLockStatus bit in the
EtherNet/IP Input Assembly.
Range: 10…10000 rpm
60
At Speed
The range in user units/s around the At Speed for setting the In-Speed Window
Digital Output (if configured) and the VelocityLockStatus bit in the EtherNet/IP Input
Assembly.
Range: -10000…+10000 rpm