50
Rockwell Automation Publication 2097-UM001D-EN-P - November 2012
Chapter 3
Kinetix 300 Drive Connector Data and Feature Descriptions
Ethernet Connections
An RJ45 Ethernet connector (port 1) is provided on the Kinetix 300 drive.
Table 15 - Ethernet Communication Specifications
24V DC Back-up Power
The Kinetix 300 drive can use an external power supply to power the logic and
communication circuits. If an independent 24V (@ 1 A) power supply is
connected to the BP connector, the logic and communication circuits remain
active during a mains input power loss.
Table 16 - 24V DC Back-up Power Specifications
Attribute
Value
Communications
100BASE-TX, full duplex
Cyclic update period
2 ms, min
Auto MDI/MDIX crossover
detection/correction
Yes
Cabling
CAT5E or CAT6, unshielded or shielded, 100 m (328 ft)
Attribute
Value
Input voltage
20…26V DC
Current
500 mA
Inrush, max
30 A
Содержание Kinetix 300
Страница 4: ...4 Rockwell Automation Publication 2097 UM001D EN P November 2012 Summary of Changes Notes...
Страница 18: ...18 Rockwell Automation Publication 2097 UM001D EN P November 2012 Chapter 1 Start Notes...
Страница 188: ...188 Rockwell Automation Publication 2097 UM001D EN P November 2012 Appendix A Interconnect Diagrams Notes...
Страница 216: ...216 Rockwell Automation Publication 2097 UM001D EN P November 2012 Appendix D MicroLogix Explicit Messaging Notes...
Страница 229: ...Kinetix 300 EtherNet IP Indexing Servo Drives User Manual...
Страница 230: ......