Configure Drive Mode with
Explicit Messaging
These Kinetix 300 drive modes can be set via explicit messaging:
•
Master Gearing
•
Step and Direction
•
Analog Velocity
•
Analog Current
•
Indexing
Set the drive mode by entering the parameters from the appropriate table via
EtherNet/IP Explicit Messaging or through the MotionView software. For
Indexing mode see
Table 62 - Master Gearing
Table 63 - Step and Direction
ID
Parameter Name
Description
Value
266
Drive Mode
Set to Master Gearing
2
79
M2SRatioMaster
Master to system ratio (master counts)
Range: -32767…32767
80
M2SRatioSystem
Master to system ratio denominator
(system counts)
Range: 1…32767
29
EnableSwitchType
Enable switch function
0 = Inhibit only
1 = Enable as soon as asserted
IMPORTANT
Do not set parameter 80 to 0 or unexpected motion will occur.
ID
Parameter Name
Description
Value
266
Drive Mode
Set to Step and Direction
3
79
M2SRatioMaster
Master to system ratio numerator
(master counts)
Range: -32767…32767
29
EnableSwitchType
Enable switch function
0 = Inhibit only
1 = Enable as soon as asserted
Содержание Kinetix 300
Страница 4: ...4 Rockwell Automation Publication 2097 UM001D EN P November 2012 Summary of Changes Notes...
Страница 18: ...18 Rockwell Automation Publication 2097 UM001D EN P November 2012 Chapter 1 Start Notes...
Страница 188: ...188 Rockwell Automation Publication 2097 UM001D EN P November 2012 Appendix A Interconnect Diagrams Notes...
Страница 216: ...216 Rockwell Automation Publication 2097 UM001D EN P November 2012 Appendix D MicroLogix Explicit Messaging Notes...
Страница 229: ...Kinetix 300 EtherNet IP Indexing Servo Drives User Manual...
Страница 230: ......