128
Rockwell Automation Publication 2097-UM001D-EN-P - November 2012
Chapter 6
Configure and Start Up the Kinetix 300 Drive
Configure the Kinetix 300
Drive Ethernet IP Address
This section offers guidance on configuring your Ethernet connection to the
Kinetix 300 drive.
Ethernet Connection
Configuration, programming, and diagnostics of the Kinetix 300 drive are
performed over the standard 10/100 Mbps Ethernet communication port by
using the MotionView OnBoard software contained within the drive itself.
To access the MotionView OnBoard software, the Kinetix 300 drive and your
personal computer must be configured to operate on the same Ethernet network.
The IP addresses of the Kinetix 300 drive, the personal computer, or both drive
and personal computer may require configuring to enable Ethernet
communication between the two devices.
Kinetix 300 Drive Ethernet Port Configuration
The IP address of the Kinetix 300 drive is composed of four sub-octets that are
separated by three dots to conform to the Class C Subnet structure. Valid
configurations for sub-octets are between 001…254. The default IP address for
any Kinetix 300 drive is 192.168.124.200.
There are two methods of changing the current IP address. An address can be
assigned to the drive automatically (dynamic IP address) when the drive is
connected to a DHCP (Dynamic Host Configuration Protocol) enabled server,
or the drive can have an IP address assigned to it manually be the user (static IP
address). Both methods of configuring the drives IP address are shown here.
TIP
To run MotionView OnBoard on a Mac OS, run the personal computer
emulation tool first.
IMPORTANT
Any changes made to Ethernet communication settings on the Kinetix 300
drive do not take effect until the drive is powered off and powered on again.
The drive continues to use the previous settings until power is cycled.
TIP
For personal computers with an Ethernet port that is used for a specific
purpose, such as email or web browsing, it may be more convenient for you to
add an Ethernet port to the personal computer.
Installing a USB/Ethernet dongle or a PCMCIA Ethernet card is an easy way to
gain an additional port for communication to the Kinetix 300 drive.
Содержание Kinetix 300
Страница 4: ...4 Rockwell Automation Publication 2097 UM001D EN P November 2012 Summary of Changes Notes...
Страница 18: ...18 Rockwell Automation Publication 2097 UM001D EN P November 2012 Chapter 1 Start Notes...
Страница 188: ...188 Rockwell Automation Publication 2097 UM001D EN P November 2012 Appendix A Interconnect Diagrams Notes...
Страница 216: ...216 Rockwell Automation Publication 2097 UM001D EN P November 2012 Appendix D MicroLogix Explicit Messaging Notes...
Страница 229: ...Kinetix 300 EtherNet IP Indexing Servo Drives User Manual...