background image

Installation Instructions

Original Instructions

440G-LZ Guard Locking Safety Switch

Catalog Numbers 440G-LZS21SJLJ, 440G-LZS21SJRJ, 440G-LZS21SPLA, 440G-LZS21SPLB, 440G-LZS21SPLH, 440G-LZS21SPRA, 440G-LZS21SPRB, 

440G-LZS21SPRH, 440G-LZS21STLA, 440G-LZS21STLB, 440G-LZS21STLH, 440G-LZS21STRA, 440G-LZS21STRB, 440G-LZS21STRH, 440G-LZS21UJLJ, 

440G-LZS21UJRJ, 440G-LZS21UPLA, 440G-LZS21UPLB, 440G-LZS21UPLH, 440G-LZS21UPRA, 440G-LZS21UPRB, 440G-LZS21UPRH, 440G-LZS21UTLA, 

440G-LZS21UTLB, 440G-LZS21UTLH, 440G-LZS21UTRA, 440G-LZS21UTRB, 440G-LZS21UTRH 

Summary of Changes

Added required minimum distance between switches and detail for 5-

pin quick-disconnect models.

Additional Resources

The QR code on the switch provides a link to publication 

440G-UM001A-EN-P.

You can view or download publications at 

http://

www.rockwellautomation.com/literature/

. To order paper copies of 

technical documentation, contact your local Allen-Bradley distributor 

or Rockwell Automation sales representative.

Introduction

Figure 1 - Assembly Overview

ATTENTION: 

Read this document and the documents that are listed 

in the Additional Resources section about installation, 
configuration, and operation of this equipment before you install, 
configure, operate, or maintain this product. Users are required to 
familiarize themselves with installation and wiring instructions, 
and requirements of all applicable codes, laws, and standards.
Activities including installation, adjustments, putting into service, 
use, assembly, disassembly, and maintenance are required to be 
carried out by suitably trained personnel in accordance with 
applicable code of practice.
If this equipment is used in a manner not specified by the 
manufacturer, the protection provided by the equipment may be 
impaired.

Topic 

Page

Summary of Changes

1

Additional Resources

1

Introduction

1

Mounting

2

Installation Considerations

2

Auxiliary/Manual Release

3

Connections

4

Resource

Description

440G-LZ Guard Locking Switch User Manual, 

publication 

440G-UM001A-EN-P

Provides general guidelines for installing a 

Rockwell Automation guard locking switch.

Industrial Automation Wiring and Grounding 

Guidelines, publication 

1770-4.1

 

Provides general guidelines for installing a 

Rockwell Automation industrial system.

Product Certifications website, 

http://

www.rockwellautomation.com/products/

certification

 

Provides declarations of conformity, 

certificates, and other certification details.

ATTENTION: 

Do not attempt to install this device unless the 

installation instructions have been studied and understood. This 
document acts as a guide for a typical installation and is available in 
some languages at www.rockwellautomation.com/literature. 
Select the publication language and type 440G-LZ in the search 
field. A user manual is also available, publication 

440G-UM001A-EN-P

Locking bolt

Actuator

Switch body

Actuator mounting 

bracket

QR Code

Alignment 

guide

Содержание Guardmaster 440G-LZS21SJLJ

Страница 1: ...s and requirements of all applicable codes laws and standards Activities including installation adjustments putting into service use assembly disassembly and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be im...

Страница 2: ...ions Figure 4 Orientation of Assembled Switch MinimumDistanceBetweenSwitches If a pair of 440G LZ switches is mounted close to each other the two inductive fields interact causing crosstalk which results in nuisance faults and false operation An absolute minimum of 200 mm 8 in must be used to help achieve correct operation The restriction applies if a 440G LZ switch is mounted close to the TLS Z g...

Страница 3: ...uator alignment by first mounting just the actuator mounting bracket to the guard door and then fit the actuator to its mounting bracket It is not possible to mechanically extend the locking bolt during installation this can only be done electrically see Commissioning in the user manual ATTENTION Afterinstallation besurethatthereisnopossibility of lifting the actuator over the extended locking bol...

Страница 4: ...e the 2 with 5 5 m 16 4 ft or 10 10 m 32 8 ft for standard cable lengths The recommended patchcord for use with ArmorBlock Guard Safety I O is the 2 m 6 5 ft catalog number 889D F5ACDM 2 Replace the 2 with 0M3 0M3 0 98 ft 1 1 m 3 28 ft 5 5 m 16 4 ft or 10 10 m 32 8 ft for standard cable lengths Color Function Pin White Aux 1 Brown 24V DC 2 Green Lock 3 Yellow Safety B 4 Grey Safety A 5 Pink Safety...

Страница 5: ...s Enclosure ingress rating NEMA 3 4X 12 13 IP66 IP67 IP69K Operating voltage Ue 24V DC 10 15 Class 2 SELV Shock and vibration IEC 60068 2 27 30 g 11 ms IEC 60068 2 6 10 55 Hz Maximum frequency of operating cycles 0 2 Hz Hygienic ISO 14159 2004 and EN 1672 2005 for that part of the machine defined as food splash area Dwell time between subsequent locking unlocking 2 5 s Washdown Sodium Hydroxide ba...

Страница 6: ...dc groups literature documents du ra du002_ en e pdf Technical Support Center Knowledgebase Articles How to Videos FAQs Chat User Forums and Product Notification Updates https rockwellautomation custhelp com Local Technical Support Phone Numbers Locate the phone number for your country http www rockwellautomation com global support get support now page Direct Dial Codes Find the Direct Dial Code f...