Publication 2364F-5.05 - March 1999
4-10
Testing Components
Testing the Isolation Board
The isolation board receives feedback from the AC line, DC bus, current
transducers, main contactor (M1), and reset button. This feedback is passed
to the main control board for processing.
Figure 4.6
Isolation Board
Note: A detailed illustration of the isolation board can be found in
Appendix A.
1. Push the disconnect lever to off and wait for all voltage to discharge
from the unit. Do not continue until all voltage has dissipated from the
DC bus.
2. Verify that there is no voltage across the DC bus (see Figure 4.12 and
Figure 4.13 for check points).
3. Verify that there is no voltage across the terminals and subcomponents
of the isolation board.
Isolation Board
SW1
TB3
TB1
TB2
TB2 is used only in
Series B units.
Note:
Burden
Resistors
TB6-6
TB6-9