296
Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
Chapter 4
Monitor the Switch
Switch Information
The Switch Information area on the Dashboard displays information about the
switch.
Table 108 - Stratix 8000/8300 Port Status Indicators
Mode
Status
Description
Status
In Status mode, the port status indicators show the status of the ports. Status is the default mode.
Off
No link
Solid green
No activity on link.
Flashing green
Link activity.
Solid brown
Port has been disabled.
Yellow
An error has disabled the port.
Flashing green and amber
Faulty link.
Flashing amber
Smartports configuration mismatch on port.
Solid amber
Port is faulty, disabled due to an error, or is in an STP-blocked state.
Duplex
In Duplex mode, the port status indicators show the Duplex mode (Full-duplex or Half-duplex) of the ports. The 10/100/1000 ports operate only in Full-duplex
mode.
Off
No link.
Solid light blue
Port is in Half-duplex mode.
Solid green
Port is in Full-duplex mode.
Speed
In Speed mode, the port status indicators show the operating speed of the ports.
Off
No link.
Solid light blue
10 Mbps
Solid green
100 Mbps
Flashing green
1000 Mbps
Table 109 - Switch Information Fields
Field
Description
Host Name
A descriptive name for this switch. The default name is Switch. You can set this parameter on the Admin > Express Setup page.
IP Address
The IP address of this switch. You can configure this setting on the Admin > Express Setup page.
MAC Address
The MAC address of this switch. This information cannot be changed.
Product ID
The model of this switch. This information cannot be changed.
License Level
The type of firmware on the switch: Full or Lite. This information cannot be changed.
CIP Revision
The version of Common Industrial Protocol (CIP) that is supported on this switch. This information cannot be changed.
CIP Serial Number
The CIP serial number. This information cannot be changed.
Serial Number
The serial number of this switch. This information cannot be changed.
Version ID
The hardware version. This information cannot be changed.
Software
The version of IOS that this switch is running. This information is updated when you upgrade the switch firmware.
Contact
The person who is the administrative contact for this switch. You can set this parameter on the Configure > SNMP page.
Location
The physical location of this switch. You can set this parameter on the Configure > SNMP page.
Содержание armorstratix 5700
Страница 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Страница 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Страница 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Страница 148: ...148 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features ...
Страница 282: ...282 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features Notes ...
Страница 317: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 317 Monitor the Switch Chapter 4 ...
Страница 319: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 319 Monitor the Switch Chapter 4 ...
Страница 325: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 325 Monitor the Switch Chapter 4 ...
Страница 338: ...338 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 5 Troubleshoot the Switch Notes ...
Страница 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Страница 404: ...404 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix B Port Assignments for CIP Data Notes ...
Страница 450: ...450 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix D Cables and Connectors Notes ...
Страница 457: ......