d327 [Status @ Fault]
Related Parameter(s):
Displays the value of
[Drive Status] when the last fault occurred.
Values
Default:
Read Only
Min/Max:
0/1
Display:
1
d328 [PID Fdbk Display]
Related Parameter(s):
(With FRN 7.xx and later.)
Displays the active PID Feedback value.
Values
Default:
0.0%
Min/Max:
-200.0/200.0%
Display:
0.1%
d329 [DC Bus Ripple V]
Related Parameter(s):
(With FRN 6.xx and later.)
Displays the real-time value of DC bus ripple voltage.
Excessive voltage ripple will eventually result in F017 Input Phase Loss fault.
Fault ripple levels are: 30V for 230V rated drives, and 60V for 460V rated drives.
Values
Default:
Read Only
Min/Max:
0/(410 for 230 VAC drives, 820 for 460 VAC drives) VDC
Display:
1 VDC
d330 [Fault 4 Code]
(With FRN 6.xx and later.)
A code that represents the fourth most recent drive fault. The codes will appear in these parameters in the order they occur (
[Fault 1 Code] = the most recent fault). Repetitive
faults will only be recorded once. As faults occur, this parameter will be overwritten by [Fault 3 Code]. The value of this parameter is then moved to [Fault 3 Code].
Refer to
for fault code descriptions.
Values
Default:
Read Only
Min/Max:
0/122
Display:
1
d331 [Fault 5 Code]
(With FRN 6.xx and later.)
A code that represents the fifth most recent drive fault. The codes will appear in these parameters in the order they occur (
[Fault 1 Code] = the most recent fault). Repetitive
faults will only be recorded once. As faults occur, this parameter will be overwritten by [Fault 4 Code]. The value of this parameter is then moved to [Fault 3 Code].
Refer to
for fault code descriptions.
Values
Default:
Read Only
Min/Max:
0/122
Display:
1
d332 [Fault 6 Code]
(With FRN 6.xx and later.)
A code that represents the sixth most recent drive fault. The codes will appear in these parameters in the order they occur (
[Fault 1 Code] = the most recent fault). Repetitive
faults will only be recorded once. As faults occur, this parameter will be overwritten by [Fault 5 Code].
Refer to
for fault code descriptions.
Values
Default:
Read Only
Min/Max:
0/122
Display:
1
Содержание 22C-B012N103
Страница 8: ...6 Rockwell Automation Publication 22C UM001J EN E January 2017 Summary of Changes Notes...
Страница 46: ...44 Rockwell Automation Publication 22C UM001J EN E January 2017 Chapter 1 Installation Wiring Notes...
Страница 56: ...54 Rockwell Automation Publication 22C UM001J EN E January 2017 Chapter 2 Start Up Notes...
Страница 154: ...152 Rockwell Automation Publication 22C UM001J EN E January 2017 Appendix B Accessories and Dimensions Notes...
Страница 176: ...174 Rockwell Automation Publication 22C UM001J EN E January 2017 Appendix E Modbus RTU Protocol Notes...
Страница 192: ...190 Rockwell Automation Publication 22C UM001J EN E January 2017 Appendix G P1 FloorLevel Network FLN Notes...
Страница 195: ......