Allen-Bradley 1770-M10 Скачать руководство пользователя страница 1

Assembly and

Installation

Manual

Mass Storage
Systems
(Cat. No.
1770M10, M11,
M12)

AllenBradley

Содержание 1770-M10

Страница 1: ...Assembly and Installation Manual Mass Storage Systems Cat No 1770 M10 M11 M12 Allen Bradley...

Страница 2: ...3 1 Installing Your System 3 1 Product Connections 3 4 Before you Connect the 1770 M1 System 3 4 Connecting to the Advisor 2 System 3 6 Connecting to the PLC 3 Peripheral Communication Module 3 7 Conn...

Страница 3: ...A 5 Back View Hardware Features A 6 How to Insert Your Micro Floppy A 6 How to Remove Your Micro floppy A 8 1770 M11 Mass Storage System B 1 Objectives B 1 Introduction B 1 Hardware Features B 1 File...

Страница 4: ...ibutor To make this manual easier to read and understand we avoid repeating product names and acronym definitions wherever possible We refer to 1770 M10 Universal Mass Storage System as 1770 M10 syste...

Страница 5: ...es Peripheral Communication Module 175 GA Programmable Controller Management System PC M Ladder Diagram Translator Software 6060 WAF3 WBF3 Data Cartridge Recorder 1770 SB Industrial Terminal 1770 T4 I...

Страница 6: ...808 PC M Ladder Diagram Translator Software publication 1770 6 5 6 formerly 1770 821 Data Cartridge Recorder User s Manual publication 1770 6 5 4 formerly 1770 806 We will be releasing new informatio...

Страница 7: ...1 B describes the type of interface system with each mass storage system Table 1 B Summary of the Mass Storage Systems Catalog Number Storage Capacity Compatible with Type of Interface 1770 M10 Unive...

Страница 8: ...J22 Test J23 RS422 Interface J24 X X X X X X X Switches Power Baud Rate X X X X Other Power Connect 120 220 V AC electrical card Fan and Filter Fuseholder X X X X X X X X X X X X Internal Components...

Страница 9: ...ppy Eject Pushbutton Winchester Disk Indicator Winchester Hard Disk Storage MASS STORAGE SYSTEM MASS STORAGE SYSTEM MASS STORAGE SYSTEM 11923 Disk Indicators There are two LED disk indicators one for...

Страница 10: ...ardware malfunction module fault Off indicates normal operation Restart Pushbutton When you press this red pushbutton labeled RESTART it causes the DMIM to load the 1770 M11 operating system program f...

Страница 11: ...Back View Hardware Features This section describes back view hardware features for each mass storage system Figure 1 2 Chapter 3 describes how to connect each mass storage system from its communicatio...

Страница 12: ...is communication port labeled SERIAL CHANNEL J22 has six slotted screws It is where the twinaxial cable connects from the 1770 M11 system to the PLC 3 peripheral communication module Test J23 Using th...

Страница 13: ...trical card protects the mass storage system from overcurrent and overvoltage You could damage your equipment if you do not insert the proper side of the electrical cord Chapter 4 describes how to cha...

Страница 14: ...specifications D Micro floppy media information and specifications A D Power supply specification D SCSI specification small computer system interface C DMIM specification disk memory interface module...

Страница 15: ...stem 3564 1002 or equivalent 1770 M10 3636 100 or equivalent 1770 M12 The 1770 M11 system comes with a micro floppy diskette labeled Operating System for PLC 3 Peripheral Communication Module Mass Sto...

Страница 16: ...ration and shock Shock levels beyond those noted in the specification appendix A may result in loss of oxide media or head misalignment i e disk failure and or permanent loss of all recorded data See...

Страница 17: ...l hardware Skip step 3 if you do not want this option 3 Connect each mounting bracket with each handle and secure with two flat head machine screws Figure 1 4 4 Line up each mounting bracket over the...

Страница 18: ...Mass Storage System Self tapping Screws 11960 Table Top Mount We place protective feet on the bottom of each mass storage system This will guard the mass storage system against slippage while it is on...

Страница 19: ...m PLC 3 Peripheral Communication Module 1770 M12 PC M Mass Storage System Programmable Controller Management System There is an internal switch assembly that contains eight switches Figure 1 6 located...

Страница 20: ...internal switch assembly for the 1770 M11 or 1770 M12 systems Damage to your equipment may occur Table 1 D 1770 M10 Switch Assembly Settings 1770 M10 System Unit Number SW1 SW2 SW3 0 ON ON ON 1 OFF O...

Страница 21: ...20V ACF then change the electrical card to 220V AC Refer to chapter 4 We ship each mass storage system for a 120V AC operation 2 Connect one end of the connector cable to the disk drive port of the Ad...

Страница 22: ...ear 1775 GA Peripheral Communication Module 1770 CD Twinaxial Cable To another Peripheral Communication Module 1770 M11 Mass Storage System 11964 1 Match the power outlet voltage to the mass storage s...

Страница 23: ...d to the 1770 M11 Mass Storage System a loosen three consecutive screws to one channel of the peripheral communication module b wrap the blue wire around the screw labeled LINE 1 secure the screw c wr...

Страница 24: ...e blue wire around the screw labeled 1 secure the screw g wrap the shield drain wire around the screw labeled SHIELD secure the screw h wrap the clear wire around the screw labeled 2 secure the screw...

Страница 25: ...ge System To another 1770 M10 system P N 966189 01 Connector Cable 1 By hand remove the internal single inline packs SIPs located on the Disk Controller Module of the 1770 M11 system Refer to Figure 1...

Страница 26: ...6189 01 Connector Cable Unit 3 1770 M10 Mass Storage System P N 966289 01 Connector Cable 11969 3 Match the power outlet voltage to the mass storage system s voltage For example if the power outlet is...

Страница 27: ...communication starts and where it ends Figure 1 14 How to Connect Multiple Peripheral Communication Modules to One 1770 M11 System Place 1770 XT Terminator Here Place 1770 XT Terminator Here SERIAL CH...

Страница 28: ...t the 1770 M12 System to the PC M System PC M Front View PC M Back View 1770 M12 Mass Storage System P N 966289 01 Connector Cable PORT 0 PORT 1 PORT 2 PORT 3 11971 1 Match the power outlet voltage to...

Страница 29: ...PC M 3 Connect the other end to J24 of the 1770 M12 system 4 Plug the power cable into the power outlet In this chapter you read how to install your mass storage system connect your mass storage syste...

Страница 30: ...rations for your 1770 M11 system begin operations for your 1770 M12 system Chapter 5 describes troubleshooting aids for your mass storage system To change the electrical card for operation follow thes...

Страница 31: ...fuse 9 Use needle noise pliers grip the electrical card firmly and remove it from J19 C FUSE PULL FUSE PULL tab D FUSE PULL Electrical card 10 Re insert the electrical card with the label 220V side sh...

Страница 32: ...rations make sure the POWER switch is at position 0 Perform the following steps for your 1770 M10 system Figure 1 16 Figure 1 16 System Start up Procedure for the 1770 M10 System 1770 M10 Mass Storage...

Страница 33: ...tem needs the software of the operating system program to communicate to the peripheral communication module This operating system program is located in two places within the hard disk unit packaged o...

Страница 34: ...munication rate by sliding the BAUD RATE switch to Position For Communication Rate 1 57 6kbaud for 10 000 ft max 2 115 2kbaud for 5 000 ft max 3 230 4kbaud for 2 000 ft max 2 Select position 1 of the...

Страница 35: ...ing system diskette with each series B 1770 M10 or M11 system To load the operating system program from its micro floppy onto the DMIM follow these steps Figure 1 18 Figure 1 18 How to Load the Operat...

Страница 36: ...he micro floppy will seat into the access slot 4 Press the RESTART pushbutton You should see the micro floppy indicator blinking red then the hard disk indicator blinking red When both indicators stop...

Страница 37: ...osition 1 of the POWER switch The POWER indicator lights green if it does not refer to chapter 5 for troubleshooting aids Refer to the PC M User s Manual publication 1770 6 5 1 formerly 1770 821 for i...

Страница 38: ...er Winchester disk or micro floppy disk indicators does not light Burned out LED Failure with an internal component Winchester disk power supply or SCSI Call your Allen Bradley sales engineer or distr...

Страница 39: ...perly seated into the disk drive Micro floppy does not contain a valid operating system program Failure of one or more of the internal components power supply micro floppy drive DMIM SCSI Connect powe...

Страница 40: ...nit address PLC 3 processor system or peripheral communication module failed 1770 M10 system address switch is not properly set Micro floppy is not properly seated into the disk drive Connect the twin...

Страница 41: ...should enjoy trouble free service We recommend two general precautions Operate your mass storage system in an environment protected from shock vibration moisture and corrosive fumes Transport your mas...

Страница 42: ...Physical Damage Non operating Series A Systems Series B Systems 2 to 22 Hz 5 to 36 Hz 0 040 inch double amplitude 0 050 inch double amplitude 22 to 500 Hz 36 to 250 Hz 1 0g 3 0g We test vibration two...

Страница 43: ...cal vapors can be removed by a filter ATTENTION Operate your mass storage system in an environment protected from corrosive vapors and where temperature and humidity are controlled Always transport yo...

Страница 44: ...access slot of the mass storage system Do not clean the micro floppies with chemicals Do not place heavy objects on the micro floppies Do not use paper clips to attach documents to the micro floppies...

Страница 45: ...ed on the micro floppy by the manufacturer and indicates the specifications of the micro floppy Temporary Label This label should be placed above the permanent label Mark the temporary label with a fe...

Страница 46: ...dle Hole Read Write Access Slot Do not touch the recording surfaces Spindle Hole This is where the micro floppy internally connects to the disk drive Read Write Access Slot This slot moves back and fo...

Страница 47: ...faces up Indicator lights green 11979 POWER 120V AC 50 60Hz 5A 250V FUSE J19 4 Select position 1 of the POWER switch If power is on the POWER indicator lights green If power is not on then refer to c...

Страница 48: ...and loss of data can occur To remove your micro floppy follow these steps Figure 1 23 Figure 1 23 How to Remove a Micro floppy from a Mass Storage System Press this pushbutton the micro floppy will ej...

Страница 49: ...clude the storage and retrieval of PLC3 memory contents PLC3 procedures data logging files There are three distinct features of this system They are hardware file management GA Basic mass storage syst...

Страница 50: ...supporting up to 4093 files on the Winchester disk drive capability of supporting up to 2153 files on the micro floppy diskette supports up to seven levels of subdirectories software supported file pr...

Страница 51: ...e Disk Memory Interface Module DMIM within the 1770M11 system You initiate the commands via a terminal connected to the PLC3 peripheral communication module using GA Basic commands and functions Gener...

Страница 52: ...l command Copy Record oriented file management commands and functions Assign Deassign Allocate Open Deallocate Close Read Write Setrecord Getchar Outchar Testchar Testline Waitchar EOF end of file Fil...

Страница 53: ...m Appendix B B 5 Remuser File and device backup commands Copy Device Store Restore We describe the use of these commands and functions in the Peripheral Communication Module User s Manual publication...

Страница 54: ...n 2 Data Bit 0 DB 0 4 Data Bit 1 DB 1 6 Data Bit 2 DB 2 8 Data Bit 3 DB 3 10 Data Bit 4 DB 4 12 Data Bit 5 DB 5 14 Data Bit 6 DB 6 16 Data Bit 7 DB 7 18 Data Bit Parity DB P 20 Ground Ground 22 Ground...

Страница 55: ...e pin 25 open or connect it to ground Reference American National Standard X3T9 2 82 2 Table 1 F RS422 Pin Assignments Pin Number Signal Abbreviation 1 Shield Shield 2 Signaling Rate Indicator SI 3 Sp...

Страница 56: ...Send Data SD 23 Send Timing ST 24 Receive Data RD 25 Request to Send RS 26 Receive Timing RT 27 Clear to Send CS 28 Terminal In Service IS 29 Data Mode DM 30 Terminal Ready TR 31 Receiver Ready RR 32...

Страница 57: ...ltage Range 120V AC 90 to 132V AC 220V AC 180 to 264 AC Frequency 47 to 63 Hz Input Current 120V AC Operation 1 5A 22V AC Operation 0 75A Environmental Conditions Operating Temperature 10o to 40oC 50o...

Страница 58: ...Pin Assignments Appendix D D 2 Physical Height 13 34 cm 5 25 in Width 42 88 cm 16 88 in Depth 42 42 cm 16 70 in Weight 30 kg 66 lb...

Страница 59: ...0 M11 Mass Storage System Storage 22 5 Mbytes Per Surface 5 6 Mbytes Per Track 9216 Bytes Per Sector 512 Bytes Sectors per Track 18 Data Transfer Rate 625 kbytes second Rotational Speed 360 RPM 1 1770...

Страница 60: ...Pin Assignments Appendix D D 4 Access Time Track to Track 23 ms Average 85ms Maximum 205ms Latency 8 33ms...

Страница 61: ...nders Series A Systems 306 Series B Systems 612 Recording Surfaces 4 Heads per Surface Series A Systems 2 Series B Systems 1 Disks 2 Data Transfer Rate 250 kbits second Access Time TracktoTrack 3ms Av...

Страница 62: ...ions Terminal 1 AC Hot Terminal 2 AC Ground Terminal 3 AC Neutral Hot Terminal 1 P F D Terminal 2 12V Terminal 3 12V Terminal 4 12V Terminal 5 Return Terminal 6 Return Terminal 7 Return Terminal 8 5V...

Страница 63: ...Pin Assignments Appendix D D 7 Output Tolerance Ripple Maximum Current Minimum Current 12V 0 5A 1 5A 50mV 6 12V 0A 0 7A 50mV 5...

Страница 64: ...ine to higher full load 0 3 to all outputs Output Power Range 10oC 50oF 20W to 100W Overvoltage Protection Threshold 5V output 6 25C 0 75V Power Limit Point all line and load conditions 140W minimum T...

Страница 65: ...Pin Assignments Appendix D D 9 Power Fail Detect 30mA minimum Adjustability 5 output 4 8V to OVP trip point...

Страница 66: ...A machine or process monitored and controlled by a PC 2 The use of computer or processor based routines for specific purposes Baud A unit of data transmission speed equal to the number of code elemen...

Страница 67: ...aried in length and can be stored in different devices and storage media See record and file organization File Creation Establishing or writing records for a file on some storage medium to bring the f...

Страница 68: ...may also be built into the terminal to handle certain kinds of transactions Interactive Computing The type of processing in which the user of the system communicates directly with the system to input...

Страница 69: ...ta that can be stored in a specific section or area For example on magnetic tape recording density is often expressed in terms of the number of bytes or characters of data that can be stored in an inc...

Страница 70: ...pendix E E 5 Twisted Pair Two insulated wires which are twisted around each other Since both wires have nearly equal exposure to any electrostatic or electromagnetic interference the differential nois...

Страница 71: ...J21 2 6 Parallel channel out J20 2 6 RS422 interface J24 2 6 Serial channel J22 2 6 Test J23 2 6 Connect 1770 M10 3 6 3 10 1770 M11 3 7 3 8 3 9 Advisor 2 color graphic system 3 6 connect 1770 M12 3 1...

Страница 72: ...o SCSI interface module 2 8 Internal fault 2 3 2 4 J J20 2 2 2 6 3 11 J21 2 2 2 6 3 6 3 11 J22 2 2 2 6 3 8 J23 2 2 2 6 J24 2 2 2 6 3 14 L Load 4 6 Regulation D 6 M Mass storage system 1770 M11 B 1 177...

Страница 73: ...J24 to SCSI module 2 2 RS422 interface to SCSI module 2 6 S SCSI 2 1 2 2 B 1 C 1 Serial channel J22 2 6 Shock A 1 Single inline pacts 3 10 SIP 3 10 Specifications 1770 M10 Storage D 3 1770 M11 Storage...

Страница 74: ...Index I 4 Vocabulary 1 1 W Warnings defined 1 2 Winchester Care of 2 7 A 1 Disk 2 2 4 5 A 1 Hard disk drive 4 5 Specifications 2 8 Technology A 1 Write Protect notch A 5 Read access 4 7 A 7...

Страница 75: ...Croatia Cyprus Czech Republic Denmark Ecuador Egypt El Salvador Finland France Germany Greece Guatemala Honduras Hong Kong Hungary Iceland India Indonesia Ireland Israel Italy Jamaica Japan Jordan Ko...

Отзывы: